Electrical load information – GSI Outdoors PNEG-338 User Manual
Page 26
26
PNEG-338 Portable Dryer Installation Manual
10. Electrical Load Information
1218
1 PH 230V
Top Auger
5
26
286
178
400
100
Bottom Auger
5
26
100
Top Fan
10 to 17
78
100
Bottom Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
5
13.2
183
98.4
225
60
Bottom Auger
5
13.2
60
Top Fan
15
39
60
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 10
52
*
3 PH 440V
Top Auger
5
6.6
96
49.2
150
60
Bottom Auger
5
6.6
60
Top Fan
15
19.5
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 10
26
*
1220
1 PH 230V
Top Auger
7.5
31
298
188
400
100
Bottom Auger
7.5
31
100
Top Fan
10 to 17
78
100
Bottom Fan
10 to 12
48
100
(2) Auxiliary
(2) 7.5
62
*
3 PH 220V
Top Auger
7.5
20
229
112
300
90
Bottom Auger
7.5
20
90
Top Fan
15
39
60
Bottom Fan
10 to12
33
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
7.5
10
123
59
200
60
Bottom Auger
7.5
10
60
Top Fan
15
19.5
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 15
39
*
1222
3 PH 220V
Top Auger
7.5
20
241
123
350
90
Bottom Auger
7.5
20
90
Top Fan
20
50
90
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
7.5
10
129
64.5
200
60
Bottom Auger
7.5
10
60
Top Fan
20
25
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 15
39
*
1226
3 PH 220V
Top Auger
10
26
271
149
350
90
Bottom Auger
10
26
90
Top Fan
25
64
90
Bottom Fan
10 to 12
33
60
(2) Auxiliary
(2) 15
78
*
3 PH 440V
Top Auger
10
13
144
77.5
200
60
Bottom Auger
10
13
60
Top Fan
25
32
60
Bottom Fan
10 to 12
16.5
60
(2) Auxiliary
(2) 15
39
*
*Auxiliaries run through load and unload breakers.
Dryer
Model #
Voltage
Motor
HP
Fuel Load
Amps
Maximum Amps
with Auxiliaries
Minimum
Amps
Recommended
Service in Amps
Branch Breaker
in Amps