Auxiliary controls on your zoneline, Caution – GE 5500 User Manual
Page 8
8
Customer Service
Troubleshooting T
ips
Care and Cleaning
Operating Instructions
Safety Instructions
Auxiliary controls on your Zoneline.
Auxiliary Controls–Terminal Connections
The auxiliary controls are located behind
the room cabinet below the control panel.
Remove the room cabinet. See the
To Remove the Room Cabinet section.
Remove the screws from the lower panel
front cover and lift the panel off.
After all desired settings have been made,
replace the panel and room cabinet by
reversing the above steps.
The owner is responsible for making all
connections and setting the appropriate
dip switches.
Insert the building hook-up wires into the
bottom of the terminal and tighten screw
securely to make the desired connections.
CAUTION:
Improper wiring may damage the Zoneline
electronics. No common busing is permitted.
Damage or erratic operation may result.
A separate wire pair must be run from
each separate controlling switch to each
individual Zoneline.
3
2
1
Motion Sensor
Door Sensor
External Fan
Central Desk Control
Common - Ground
White - Heater
Yellow - Compressor
Black - Solenoid
Green - High Speed Fan
Green - Low Speed Fan
Red - 24 V AC only
Motion Sensor (Obtained locally)
When connected, the wall mounted motion
sensor will detect motion in the room and
automatically turn the unit ON or OFF.
The door and motion sensors work together
to automatically turn the unit ON or OFF.
Motion Sensor
Remove screws
and panel to access
terminal connections