beautypg.com

Heater parts removal and installation – GSI Outdoors 100 SERIES DRYER PNEG-552 User Manual

Page 40

background image

40

PNEG-552 100 Series Dryer

7. Service

Heater Parts Removal and Installation

Most of the heater parts can be removed by identifying attached wiring and disconnecting the obvious
mounting parts.

1. Flame sensor: Disconnect the wire connector and unscrew the flame sensor out of its mounting

bracket.

(See Figure 7E.)

IMPORTANT: Flame sensor has voltage present. Turn OFF main

disconnect before removing or adjusting.

2. Gas solenoid valve coil: Unsnap either the plastic cap or the metal clip on the gas valve and slide

the housing and coil off the valve stem and body. Do not energize the coil when it is removed, as
the coil may become damaged due to excessive current flow.

(See Figure 7E.)

3. Regulator and gas solenoid valve(s): The gas regulator and solenoid valve(s) are directional

and must be connected as indicated by the markings near the port openings. Make sure gas is shut
OFF and purged from the system before removing parts.

(See Figure 7E.)

NOTE: When installing a liquid gas solenoid valve on LP models, do not overtighten the connection

into the inlet side, as the inlet orifice may become partially blocked.

Figure 7E

4. Main Gas Orifice: With fuel shut OFF and gas purged from system

(See Figure 7E)

, proceed

as follows:

a. Disconnect the plumbing support brackets from the pipetrain.

b. Disconnect gas solenoid valve coils. Be sure to mark which one goes where.

c. Lift pipe (with orifice, solenoid valve and other parts attached) straight up and remove from fan

heater housing. Orifice and other parts can now be removed from pipe train, if desired.