beautypg.com

Installation instructions, Commissioning – Stovax Ceramica Gazco Ceremica Log Effect Stove Range User Manual

Page 14

background image

1. COMMISSIONING

1.1 Close all openable doors and windows in the room, ignite

the stove and operate on maximum for 10 minutes. Position

a lighted smoke match just inside the draught diverter

opening and check that all smoke is drawn into the opening.

See diagram 1. If there is any doubt, run the stove for a

further 10 minutes and repeat the test.

1.2 If there are any extractor fans in adjacent rooms, the test

must be repeated with the fans running on maximum and

interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE

APPLIANCE AND SEEK EXPERT ADVICE.
For future reference record the installation details on the

commissioning sheet at the end of the User Section of these

instructions.

14

INSTALLATION INSTRUCTIONS

COMMISSIONING

AR1493

1