beautypg.com

Furuno – Furuno NX-700B User Manual

Page 69

background image

FURUNO

NX-700A/B

SP - 2

E5649S01D-M

4 ANTENNA

UNIT

4.1 Antenna type

NX-7H: H-field antenna

4.2 Output impedance

50 ohms

4.3 Power supply

+7 V to +9 V (thru co-ax cable)

5 INTERFACE
5.1

Input data

IEC61162-1, -2

GGA, GLL, RMC, ZDA, NRQ, NMK, ACK, GNS, VHW, VTG, VBW

Output data

NRX, ALR

5.2

Alarm Normal close, contact closure signal (floating, max. 80 mA, 50 V)

for SAR alert

6 POWER

SUPPLY

6.1 NX-700A

12-24VDC: 1.5-0.8A

6.1 NX-700B

12-24VDC: 0.7-0.4A

7 ENVIRONMENTAL

CONDITION

7.1 Ambient

temperature

Antenna unit

-25°C to +70°C

Receiver / Display unit -15°C to +55°C

7.2 Relative humidity

95% at 40°C (without dew condensation)

7.3 Waterproofing

Antenna unit

IP66

Receiver / Display unit IP20 (NX-700B: IP25 for front panel)

7.4 Vibration

- 2Hz to 5 Hz and up to 13.2 Hz with a deviation of ±1 mm ±10%

(7 m/s2 maximum acceleration at 13.2 Hz);

- above 13.2 Hz and up to 100 Hz with a constant maximum

acceleration of 7 m/s

2

.

8 COATING

COLOR

8.1 Display unit

N3.0

8.2 Receiver

unit

N3.0

8.3 Antenna

unit

N9.5

This manual is related to the following products: