6
Port, cable and connectable equipment
Used cable
Port
Name
Name Type Code
No.
Standard/
Option
Connectable
Equipment
TB-1
Power
cable
14AWG-2C-PVC
*5M*
000-154-337
Standard Power
source
DVI-D
DVI
Cable
DVI-D/D
SINGLELINK5M
000-149-054
Option
PC,
FAR-21X7 series
RGB1
3COX-2P-6C
5M
000-146-500
Option
RGB2
Analog
RGB
Cable
3COX-2P-6C
10M
000-146-501
Option
FCV-1200L/1200LM,
CH-250, CH-270,
CSH-5L/8L,
FSV-24/24S,
GD-280/380/680,
FR-1500 MK3 series,
FR-21X5 series,
NavNet vx2
VIDEO1
VIDEO2
VIDEO3
Prepare the following cable locally.
▪ Connector type: RCA (metal), both ends
▪ Cable length: Max. 10 m
▪ 2.5C2V or 3C2V (Japan Industrial Standard, or the
equivalent) coaxial cable (Impedance: 75 Ω)
Conductor
S = 0.19 mm
∅
= 0.5 mm
2
Shield
Insulator
Vinyl
sheath
Cable 3C2V
Video cassette
recorder, CCD camera,
DVD player
Grounding
Fasten a ground wire (dockyard supply) and the gray crimp-on lug of the power cable to the
ground terminal together. The length of the ground wire should be as short as possible.
Note: Use a “closed-type” lug (
) to make the ground connection. Do not use an
“open-type” lug (
).