Appendix: Installation

(3)Any part of the drainpipe should be below the outlet of the indoor unit

and the joints should be wrapped with waterproof adhesive tape to

prevent leakage of condensed water.

(4)Bind the tubes, wires and the drainpipe tightly with binding tape, with

the drainpipe under the wires.

(5)Press down the clamping plate of the tubes and fix the bound wires.

Install the indoor unit

(1)Pull the bound wires out through the wall hole and put the indoor wires

together with the indoor unit at the corresponding place of the wall plate.

(2)Hook the indoor unit onto the retaining claws on the wall plate and

move the unit body slightly to make sure that it is firm.

(3)Hold the two sides of the unit body and press it to the wall plate to

ensure secure connection.

4. Installation of the outdoor unit

Mount the outdoor unit

A. Mount the outdoor unit in the selected place.

B. If the outdoor unit is to be mounted on the wall, the wall and the

installation bracket should have sufficient intensity to bear the weight of

the outdoor unit.

(1)Place the outdoor unit carefully onto the bracket.

(2)Fix the unit onto the bracket with four bottom bolts. The bolts should

have anti-vibration pads to prevent falling down of the unit from vibration.

Connect the tubes of the outdoor unit

A. Electric wires

(1)Remove the wire cover of the outdoor unit with a screwdriver.

(2)Remove the wire clip.

(3)Connect the wires to the corresponding terminals on the terminal

panel.

(4)Tighten all the screws to ensure good connection.

(5)Put the wires into place with a clip and replace the wire cover.

B. Tubes

The connection of the outdoor tubes is the same as steps (1) and (2) of

the indoor unit.

Caution: All the " Y " -shaped terminals should be plugged into

the line bank and the grounding loop terminal should be

connected fully.

Caution: Never put extra wires into the wire compartment to

avoid damage from eddying flow heating.

Wire cover

Wire outlet

Tubes

Drainpipe

Tube clamping plate

Wires

Tubes

Drainpipe

Wall plate

Tubes

Wires

Drainpipe

Tube clamping plate