beautypg.com

Operation and performance – haier AU422BIBAA User Manual

Page 13

background image

Operation and performance

3 minutes delay function

If start the unit immediately after its stop, the compressor will operate after 3

minutes have elapsed to protect the unit.

The characteristic of HEATING operation

During operation, if the outdoor temperature is too high, the fan motor of

outdoor unit will automatically change to low fan speed.

About Defrosting operation in Heating operation

During HEATING operation, when the outdoor unit frosts, in order to enhance
the heating effect, the unit will automatically start DEFROSTING operation (about
2~10 minutes), at this time, the condensate water will be drained out from outdoor
unit.
During DEFROSTING operation, the fan motor of indoor unit will be in low
fan speed or stop, the fan motor of outdoor unit will stop.

The working condition of the air conditioner

In order to use the air conditioner correctly, please operate it in the following

condition.

D.B. 18* W.B. 14*

The operation range of the air conditioner

COOLING
DEHUMIDIFYING

Indoor side

Maximum

Outdoor side

D.B. -7* W.B. -8*

D.B. 24* W.B. 18*

D.B. 43* W.B. 26*

D.B. 32* W.B. 23*

D.B. 18*
D.B. 27*
D.B. 15*

HEATING

Minimum

*

*

Note:

If the air conditioner operates out of this range for a long time, the protection
device will act and at the same time the outdoor unit will give alarm.
In the working condition of simultaneous COOLING and HEATING, when
the outdoor temperature T1* 28*, HEATING will not operate; when the
outdoor temperature T1* 7*, COOLING will not operate.
When wrong action occurs during operation
During operation, because of the influence of thunder, automobile and
wireless disturbance, the unit has wrong action, cut off the power switch,
after powering on again, press ìON/OFFî button, the unit can be turned on
or off.
About the HEATING capacity
HEATING operation adopts the heat pump type of absorbing the outdoor heat to
release to indoor side, so if the outdoor temperature drops, the HEATING capacity
may be lowered.
When the outdoor temperature is low, the air conditioner can be used together
with other heating devices.
For details, please refer to the operation manual of indoor unit.

Outdoor side

Indoor side

Maximum
Minimum
Maximum
Minimum
Maximum
Minimum

11