SECTION 6 − OPERATING THE WELDING GENERATOR

4

1

3

6

6-1. Front Panel Controls

281 080-A

1

Engine Control Switch

Use switch to start engine, select speed, and

stop engine. In Run/Idle position, engine runs

at idle speed at no load, and weld/power speed

under load. In Run position, engine runs at

weld/power speed.
2

Engine Choke Control

Use control to change engine air-fuel mix.
To Start: pull out choke and turn Engine Con-

trol switch to Start position. Release switch

and slowly push choke in when engine starts.

.

If the engine does not start, let engine

come to a complete stop before attempt-

ing restart.

To Stop: turn Engine Control switch to Off

position.
3

Engine Hour Meter/Idle Control

Hour Meter: With engine off, place Engine

Control switch in Run/Idle position to view en-

gine hours.
4

Weld Process Selector Switch

NOTICE − Do not switch under load.
Use switch to select type of weld output.
Use DC Weld (+) position for Direct Current

Electrode Positive (DCEP). Use AC position

for alternating current.
5

Coarse Range Switch

NOTICE − Do not switch under load.
Use switch to select weld amperage range.

.

For best arc starts and when using weld
and generator power together, use a low

Coarse Range setting with the Fine con-

trol set at 7 or higher.

6

Fine Control

Use control to select weld amperage within the

range selected by the Coarse Range switch.

Control may be adjusted while welding.
Set control at 10 for maximum generator

power.
Weld output would be about 110 A DC based

on control settings shown (80% of 70 to 150

A). Settings shown are typical for welding with

a 7018 (1/8) electrode.

.

See Sections 6-3 for typical process con-

nections and control settings.

5