TROUBLESHOOTING

Nothing happens; fan does not move.

Noisy operation.

Excessive Wobbling

1. Power turned off, fuse blown, or cir-

cuit breaker tripped.

2. Loose wire connections or wrong

connections.

3. Motor reversing switch not engaged.
4. Pull chain switch not “on.”
5. No oil or low oil level.

1. Blade brackets screwed loosely to

motor.

2. Blade screwed loosely to blade iron.
3. Blade cracked.
4. Canopy contacting ceiling.
5. No oil or low oil level.

1. Unbalanced blades.
2. Inadequate blade clearance.
3. Loose blades or blade irons.
4. Fan not secure on hanger assembly.

PROBLEM

PROBABLE CAUSE

SOLUTION

1. Turn power on, replace fuse, or reset breaker.
2. Loosen canopy, check all connections according to

STEP 5 - WIRING INSTRUCTIONS (turn power
off before checking).

3. Push switch firmly up or down.
4. Pull switch chain.
5. Check the oil level according to STEP - CARE

AND MAINTENANCE (turn fan off before
checking.)

1. Tighten screws until snug.
2. Tighten screws until snug.
3. Replace all blades.
4. Lower canopy.
5. Check the oil level according to STEP - CARE

AND MAINTENANCE (turn fan off before
checking.)

1. Rebalance. (See Step 7 sub-step 4.)
2. Relocate Fan.
3. Tighten all screws.
4. Turn power off. Support fan very carefully.

Loosen canopy and hang correctly.

Note: If blades will not turn by hand, contact your nearest service representa-
tive or dealer for assistance.

If you have tried these troubleshooting solutions and still have trouble,
call 901-248-2222 or visit our Web site at http://www.hunterfan.com.

Hunter Fan Company

2500 Frisco Avenue

Memphis, TN 38114

USA

© 2001 Hunter Fan Co.

The Inside Story

Oil is constantly pumped up the spiral groove

to lubricate the rotor and the shaft. The oil is
returned to the reservoir where the bearings are
submerged in a bath of oil.

This unique lubrication system is built into all

Original

®

Hunter Ceiling Fans. That’s one reason

Hunters last so long, and why we can offer a
Limited Lifetime Warranty.

Should you move you fan to another location,

it is a good idea to check the oil reservoir. Hunter
has developed an accessory “Original

®

Relocation

Kit” that includes all mounting hardware and a
fresh tube of oil for this reason. The model number
is 22360.

We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
Record the following information for your records and warranty assistance. Please refer to the carton and the

Hunter nameplate (located on the top outside fan motor housing) for the proper information.
Model Name ______________

Catalog No. _________________ Serial No.______________

Date Purchased ____________

Where Purchased ________________________

Figure 19

This manual is related to the following products: