3 – installation, 1. installing welding gun, 2. changing polarity – Hobart Welding Products 150 User Manual
Page 16: 3. process/polarity table
OM-210 088 Page 12
SECTION 3 – INSTALLATION
3-1.
Installing Welding Gun
Ref. ST-802 024
1
Drive Assembly
2
Gun Securing Thumbscrew
3
Gun End
Loosen thumbscrew. Insert gun
end through opening until it bottoms
against drive assembly. Tighten
thumbscrew.
4
Gun Trigger Leads
Insert leads, one at a time, through
small grommet on front panel. Con-
nect female friction terminals to
matching male terminals in unit.
Polarity is not important.
Close door.
4
1
2
3
3-2.
Changing Polarity
1
Lead Connections For Direct
Current Electrode Positive
(DCEP)
2
Lead Connections For Direct
Current Electrode Negative
(DCEN)
Always read and follow wire
manufacturer’s recommended po-
larity, and see Section 3-3.
Close door.
1
Ref. ST-802 024
2
3-3.
Process/Polarity Table
Cable Connections
Process
Polarity
Cable To Gun
Cable To Work
GMAW – Soild wire with shield-
ing gas
DCEP – Reverse polarity
Connect to positive (+) out-
put terminal
Connect to negative (–) output
terminal
FCAW – Self-shielding wire –
no shielding gas
DCEN – Straight Polarity
Connect to negative (–)
output terminal
Connect to positive (+) output
terminal