Installation – Hotpoint LI2SNA User Manual
Page 3
UK
! It is important to conserve this booklet for
consultation at any moment. In the case of sale,
cession or move, make sure it is together with the
product.
! Read the instructions carefully: there is important
information about installation, use and safety.
! Do not carry out electrical or mechanical variations
on the product or on the discharge conduits.
Installation
Electric connection
! The power tension must correspond with the tension
shown on the characteristics label situated inside the
hood. If provided with a plug, attach the hood to a
socket conforming to the regulations in force and
placed in an accessible zone. If without a plug,
(
connected directly to the power supply
), use a
regulation bipolar switch with a distance of the
contacts on opening not less than 3mm (
accessible
).
! If necessary, the situating of the supply cable must
be carried out by the technical assistance service or a
qualified person.
! An authorized installer must carry out the electrical
connection of the hood.
! The company declines any responsibility whenever
these regulations are not respected.
Preliminary information for installation of the hood:
Disconnect the hood during electrical connection, by
turning the home mains switch off.
Expansion wall plugs are provided to secure the hood
to most types of walls/ceilings. However, a qualified
technician must verify suitability of the materials in
accordance with the type of wall/ceiling. The
wall/ceiling must be strong enough to take the weight
of the hood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Do not fix chimney flue to furniture or fly over shelves
unless the chimney flue can be easily removed, in
case maintenance is ever required.
Where foreseen remove the grease collecting panels.
Remove the grease filter/s
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Do not fix chimney flue to furniture or fly over shelves
unless the chimney flue can be easily removed, in case
maintenance is ever required.
The minimum distance between the supporting surface
for the cooking vessels on the hob and the lowest part
of the range hood must be not less than 50cm from
electric cookers and 65 cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify
a greater distance, this must be adhered to.
1. Using a pencil, draw a line on the wall, extending up
to the ceiling, to mark the centre. This will facilitate
installation.
2. Rest the drilling template against the wall: the
vertical centre line printed on the drilling template must
correspond to the centre line drawn on the wall, and
the bottom edge of the drilling template must
correspond to the bottom edge of the hood: bear in
mind that, when installation is complete, the underside
of the hood must be at least 50 cm above the cooker
top in the case of electric cookers, and at least 65 cm
above the cooker top in the case of gas or mixed
cookers.
3. Rest the support bracket on the drilling template so
that it coincides with the dotted rectangle, mark the two
outer holes and drill them, remove the drilling template,
insert 2 wall plugs and fix the hood support bracket
into place using two 5x45mm screws.
4. Hang the hood on the bracket.
5. Adjust the distance of the hood from the wall.
6. Adjust the horizontal position of the hood.
7. Using a pencil mark the cooker hood permanent drill
hole inside the suction group (two drill holes are
necessary for fastening).
8. Remove the hood from the bracket.
9. Drill at the point marked (Ø8mm - see operation 7).
10.Insert 2 wall plugs.
11. Rest the chimney support bracket „G“ against the
wall, touching the ceiling. Use the support bracket as
a drilling template (the small slot formed on the support
must coincide with the line drawn on the wall as above
Installation