Wall mount back bar unit cooler – Heatcraft Refrigeration Products H-IM-77D User Manual
Page 12
![background image](/manuals/98043/12/background.png)
12
Wall Mount Back Bar Unit Cooler
Dimensional Diagram
Mounting
The.Wall.Mount.Back.Bar.Unit.Cooler.is.a.low.height.unit.designed.for.undercounter.applications..Air.is.drawn.in.at.the.bottom.
of.the.unit.and.discharged.out.the.front..Two.mounting.angles.are.included.with.the.unit.and.should.be.installed.to.space.the.
unit.3/4”.off.the.wall..Air.deflector(s).are.included.and.can.be.mounted.over.the.top.half.of.the.fan.guard.to.direct.the.air.up..
The.deflector.may.be.left.off.if.total.horizontal.air.movement.is.desired..If.used,.the.deflector.can.be.field.formed.to.direct.the.
air.where.needed..Locating.holes.and.screws.are.provided.
Dimensional Data
Approx.
Model
BTUH
Motor Data
Dimensions (In.)
Ship Wt.
BB
10°F TD
CFM
Qty.
HP
W
A
B
C
D
E
F
(Lbs.)
L10
1,000
90
1
1/150
19
/
4
19
1
/
8
18
17
1
/
2
7
1
/
16
-
16
5
/
8
17
M11
1,100
90
1
1/150
19
/
4
19
1
/
8
18
17
1
/
2
7
1
/
16
-
16
5
/
8
16
L15
1,500
180
2
1/150
26
1
/
4
25
5
/
8
24
1
/
2
24
4
1
/
16
8
5
/
8
2
1
/
8
20
M16
1,600
180
2
1/150
26
1
/
4
25
5
/
8
24
1
/
2
24
4
1
/
16
8
5
/
8
2
1
/
8
19
Low
-10°F Sat. Suction Temp.
-15°F Sat. Suction Temp.
Temp
BTUH @ R-404A
BTUH @ R-404A
Model 10°F TD
Alco
Sporlan
15°F TD
Alco
Sporlan
BBL10
1000
HFS-1/8SZ
EFS-1/8Z
1500
HFS-1/8SZ
EFS-1/8Z
BBL15
1500
2250
HFS-1/4SZ
EFS-1/6Z
Med
25°F Sat. Suction Temp.
20°F Sat. Suction Temp.
Temp
BTUH @ R-22
BTUH @ R-22
Model 10°F TD
Alco
Sporlan
15°F TD
Alco
Sporlan
BBM11
1100
HFS-1/4HC
EFV-1/5C
1870
HFS-1/4HC
EFV-1/5C
BBM16
1600
2720
Expansion Valve Recommendations
Description
All Sizes Part No.
115V Motor
2500701
208/20V Motor
2500801
Fan Blade
5101B
Fan Guard
5054D
Motor Mount
91179001
NOMENCLATURE
BB L S 10 A G
A = 115-1-60
B = 208/20-1-60
Revision
Back Bar Unit Cooler
L = Low Temp Unit
M = Med. Temp Unit
Size
Blank = Std. Unit
S = Slave Unit
M = Master Unit
FOR FOOD
SERVICE
INSTALLATIONS
. . . seal any joint
between unit cooler and
cooler liner with a sealant
listed by the National
Sanitation Foundation,
Standard 51
NOTE: All units have /8 O.D. suction, 1/2 O.D. sweat inlet connection and 1/2 O.D. drain.
Commercial Refrigeration Parts
Replacement Parts