©2010 Hunter Fan Co.

42018-01 20100609

CHangIng THe HePa fIlTer

When the filter exceeds 8000 hours

(approximately 1 year of use), the Filter Life

Counter will display 0% life remaining and the

Filter indicator will flash. This is a reminder

that you should check the filter and replace

if necessary. The proper time to change the

filter depends on usage and the environment.

Use the following list to help determine if the

filter should be changed:

• Compare the color of the filter to the color

coded chart on the inside of the housing. If

the filter color matches the darkest color on

the chart, you should replace the filter.

• If you notice a decrease in air output or

an increase in noise at any time during

normal operation, the filter may be clogged.

Replace the filter to return to normal

operation.

To change the filter and reset the Filter Life

Counter:

1. First, turn off and unplug the air purifier.

2. Next, remove the front grill. Place your

fingers in the recesses on either side of the

top of the grill and pull firmly.

3. Gently pull on the filter to remove it from

the unit. While removing the filter, note the

directional arrows printed on the side of the

filter. The new filter will be installed with the

same orientation. Once removed, the used

filter can be discarded.

4. Remove the new filter from its wrapping

and look at the directional arrows printed

on the side of the filter. Install the filter with

arrows pointing towards the unit. Press

the filter firmly into the air purifier. To avoid

damaging the filter media, you should press

on the frame of the filter only.

5. Reinstall the grill by first lining up the tabs

on the bottom of the grill with the openings

on the air purifier base and then pushing

the top of the grill forward until it is closed.

CHangIng THe Pre-fIlTer

When the Pre-Filter exceeds 2000 hours

(refer to Filter Life Counters for additional

information), the Pre-Filter Life Counter will

display 0% life remaining and the Pre-Filter

indicator will flash as a reminder that you

should replace the pre-filter. To maintain

proper odor-removing capability and overall

filtration performance, the pre-filter should be

changed every 2000 hours (approximately 3

months of use). If necessary, the pre-filter can

be changed more often. Proper maintenance

of the pre-filter will help extend the life of the

HEPA filter.

1. First, turn off and unplug the air purifier.

2. Next, remove the front grill. Place your

fingers in the recesses on either side of the

top of the grill and pull firmly.

3. The pre-filter is attached to the inside of the

grill with hook tape. Pull gently on the pre-

filter to remove it.

4. If needed, use a soft damp cloth to wipe off

the grill.

5. Install the new pre-filter by placing it in the

grill and pressing gently on the pre-filter so

that it adheres to the hook tape. You may

notice a few black particles coming off the

pre-filter. Those particles are part of the

odor-removing activated carbon and will be

collected on the filter during regular use.

6. Install the grill back onto the unit. First, line

up the tabs on the bottom of the grill with

the openings on the purifier base and then

push the top of the grill forward until it is

closed.

7. Plug in the air purifier.

NOTE: This unit will not operate unless the

grill is in the correct position.

8. Finally, reset the Pre-Filter Counter by

pressing the PRE-FILTER RESET key for 2

2. To unlock the key pad, press and hold

the UP/DOWN keys simultaneously for

2-3 seconds. The Keypad Indicator will

disappear and the keypad will be functional.

seconds. The Pre-Filter Counter will return

to 100% and the Pre-Filter indicator will

stop flashing.