Command data chart – Hitachi CP-S860E User Manual
Page 29

29
Connection to the control signal terminal (continued)
The command code configuration consists of a 2-byte command and the following data.
• The first byte of a command indicates the command type with 3 bits on the MSB side and the data length
with 4 bits on the LSB side.
Projector - computer
Computer - projector
‘0xH’ : Error code
‘2xH’ : inquiry code
‘1xH’ : response code
‘3xH’ : setting code
‘70H’ : frame error code
‘4xH’ : default setting code
‘x’ indicates the data length (example: x=2 means a 2-byte command).
• The second byte of a command indicates the command contents.
Command data chart
Item
Data code
MOUSE
00h=disable mouse function, 01
∼
7Fh=start mouse function
COMMUNICATE
0Xh=8N1, 1Xh=7N1
X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps
POWER
3Eh=power off (standby status), 3Fh=power on
ZOOM
01
∼
3Fh=Zoom+, 41
∼
7Fh=Zoom-, 01, 04 (zoom out)
∼
3F, 7F (zoom in)
FOCUS
01
∼
3Fh=Focus+, 41
∼
7Fh=Focus-, 01, 04 (short)
∼
3F, 7F (long)
MIRROR
00h=Normal, 01h=H : Invert, 02h=V : Invert, 03h=H & V : Invert
INPUT
11h=VIDEO, 21h=RGB1, 22h=RGB2
SYSTEM (VIDEO)
00h 00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4. 43
00h 02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL, 00h 06h=N-PAL
VOLUME
00h (low volume)
∼
24h (high volume)
MUTE
00h=mute off, 01h=mute on
BRIGHT
00h 00h 00h (dark)
∼
00h 00h 24h (bright)
CONTRAST
00h 00h 00h (low)
∼
00h 00h 24h (strong)
COLOR
00h 00h 00h (pale)
∼
00h 00h 24h (dense)
TINT
00h 00h 00h (reddish)
∼
00h 00h 24h (greenish)
SHARPNESS
00h 00h 00h (soft)
∼
00h 00h 24h (sharp)
H.PHASE
00h 00h 00h
∼
00h 00h 24h
H.POSIT
00h 00h 00h 01h (Right) moves one step
00h 00h 00h 7Fh (Left) moves one step
H.SIZE
00h 00h 00h 01h (Large) moves two step
00h 00h 00h 7Fh (Small) moves two step
V.POSIT
00h 00h 00h 01h (Up) moves one step
00h 00h 00h 7Fh (Down) moves one step
COLOR BALANCE R
00h 00h 00h (Light red)
∼
00h 00h 24h (Dark red)
COLOR BALANCE B
00h 00h 00h (Light blue)
∼
00h 00h 24h (Dark blue)
AUTO ADJUST
00h (AUTO ADJUST (Play)), 07h (AUTO ADJUST (stop))
BLANK
0Xh=blanking off, 1Xh=blanking on
X=8 Black, X=9 Blue, X=F White
MAGNIFY
(1) Inquiry code, response code in case of having sent default setting code (data length=1 byte)
00h=normal display, 01h=magnified display
(2) In case of setting magnification rate of the setting code (data length=6 bytes)
1st, 2nd data byte: starting position for horizontal magnification (left end) 00h 00h (left) ~ 30h 05h (right)
3rd, 4th data byte: starting position for vertical magnification (upper end) 00h 00h (up) ~ 00h 04h (down)
5th, 6th data byte: data for number of dots for horizontal magnification 64h 00h (large) ~ 20h 06h (small)
FREEZE