English

6.1

CONNECTIONS

Connections on pressure washer hoses, gun and spray

wand should be cleaned regularly and lubricated with

light oil or non-water soluble grease to prevent leakage

and damage to the o-rings.

6.2 NOZZLE
Clogging of the nozzle causes the pump pressure to be

too high and cleaning is immediately required.

1. Clear the nozzle by forcing a stiff wire through

center hole.

2. Backflush the nozzle with water.
3. Reconnect the nozzle to the wand.

6.0 MAINTENANCE

6.3

LUBRICATION

The pressure washer is designed with a permanent

lubrication system. Conventional oil check and oil

changes are not necessary.

NOTE: IN CASE OF OIL LEAKAGE, CONTACT THE

CUSTOMER SERVICE DEPARTMENT CONCERNING

REPAIR. A SMALL AMOUNT OF OIL LEAKAGE IS

NORMAL. www.huskypowerwasher.com.

6.4 WATER

SCREEN

The pressure washer is equipped with a water inlet

screen filter to protect the pump.

CAUTION: If the screen is not kept clean,

the flow of water to the pressure washer

will be restricted and the pump may be

damaged.

To clean inner water screen, remove the inlet nipple

and remove the filter screen from the inlet.

Backflush screen to clean.
Replace screen and inlet nipple immediately to pre-

vent any foreign matter from entering the pump.

CAUTION: Do not damage the screen

while removing or cleaning. Any foreign

particles entering the pump may damage

the pump.

6.5 COOLING

SYSTEM

The air vents, located in and around the pressure

washer, must be kept clean and free of any obstruc-

tions to ensure proper air cooling of the motor during

operation.

WARNING: Prevent water from pene-

trating the vents of the pressure washer

to minimize the risk of damage to the

machine and to reduce the risk of shock

to the operator.

CAUTION

CAUTION

WARNING

7.0 SERVICING A DOUBLE-
INSULATED

APPLIANCE

In a double-insulated product, two systems

of insulation are provided instead of

grounding. No grounding means is pro-

vided on a double-insulated product, nor

should a means for grounding be added

to the pressure washer. Servicing a double-insulated

product requires extreme care and knowledge of the

system, and should be done only by qualified service

personnel.

Replacement parts for a double-insulated product

must be identical to the parts they replace. A double-

insulated product is marked with the words “DOUBLE-

INSULATION” or “DOUBLE-INSULATED”. The symbol

above may also be marked on the product.