I. specifications, A. nameplate ratings, B. dimensions – Hoshizaki HUR40A(-D) User Manual
Page 5: A. nameplate ratings b. dimensions, I. specifications a. nameplate ratings

5
Undercounter Model Names
The undercounter models covered in this service manual initially had different model
names. If you have a unit with an auxiliary code of N-6 and a serial number ending in "H",
refer to the table below.
Model Name on
Nameplate
Current
Name
UR1-SSB
HUR40A
UR2-SSB
HUR68A
UF1-SSB
HUF40A
UF2-SSB
HUF68A
I. Specifications
A. Nameplate Ratings
Design Pressure
(PSIG)
Refrigerant
(oz.)
Model
AC Supply Voltage
Amperes
HI
LO
404A
134a
HUR40A(-D), HWR40A(-D)
115/60/1
5.0
240
120
15.2
HUR68A(-D), HWR68A(-D)
115/60/1
5.0
240
120
15.2
HUR96A(-D), HWR96A(-D)
115/60/1
6.0
240
120
15.2
HUF40A(-D), HWF40A(-D)
115/60/1
5.5
450
250
14.1
HUF68A(-D), HWF68A(-D)
115/60/1
10.0
450
250
13.0
Model
Door Opening mm
Total Refrigerated
Volume ft
3
Total Shelf
Space ft
2
Hotel Pan
Capacity (-D)
Width
Height
HUR40A(-D), HWR40A(-D),
HUF40A(-D), HWF40A(-D)
570.2
616.2
8.5
7.6
4
HUR68A(-D), HWR68A(-D),
HUF68A(-D), HWF68A(-D)
18.8
17.1
8
HUR96A(-D), HWR96A(-D)
29.1
26.6
12
B. Dimensions