User-maintenance instructions – Harbor Freight Tools 98917 User Manual
Page 12
SKU 98917
For technical questions, please call 1-800-444-3353.
Page 12
USER-MAINTENANCE
INSTRUCTIONS
Procedures not specifically
explained in this manual
must be performed only by a
qualified technician.
TO PREVENT
SERIOUS INJURY
FROM ACCIDENTAL
OPERATION:
Turn off the tool, detach the
air supply, safely discharge
any residual air pressure in
the tool, and release the
Trigger before performing any
inspection, maintenance, or
cleaning procedures.
TO PREVENT SERIOUS
INJURY FROM TOOL
FAILURE:
Do not use damaged
equipment. If abnormal
noise, vibration, or leaking
air occurs, have the problem
corrected before further use.
Cleaning, Maintenance, and
Lubrication
Note: Anytime inspection, maintenance
and cleaning are done:
1.
Disconnect the Floor Nailer from
its air supply.
2.
Empty the Magazine (71) complete-
ly.
3.
Try to fire the Nailer into a piece of
scrap wood or flooring to ensure
that it is disconnected and inca-
pable of firing any nails/staples.
4. Inspect the air supply screen located
in the End Cap (82) before each use.
Clean or replace as necessary. Dirt
in the air supply is a major cause of
pneumatic tool wear. Use a filter in
the compressed air system for better
performance and longer tool life. The
filter must have adequate flow capac-
ity for the specific application.
5. Clean the external parts of the Nailer
with a clean cloth and mild detergent
or non-flammable solvent. Then dry.
6. Store in a clean, dry and safe location
out of reach of children.
All maintenance, service or repairs
not listed in this manual are only
to be attempted by a qualified ser-
vice technician.
Record Product’s Serial Number
Here:
Note: If product has no serial number,
record month and year of purchase
instead.
Note: Some parts are listed and shown for
illustration purposes only, and are not
available individually as replacement
parts.