beautypg.com

Specifications – Harman Stove Company FireLuxe Direct Vent Gas Stove With Top Cooking Burner System User Manual

Page 5

background image

5

SPECIFICATIONS

MAIN BURNER

Natural Gas

Propane (LP)

Input Rating-Btu/hr

36000

36000

Min. Input-Btu/hr

23000

23000

Orifice-DMS

#34

#50

COOKING BURNER
Input Rating-Btu/hr

12000

12000

Min. Input-Btu/hr

3500

3500

Orifice-DMS

#52

#58

GAS SUPPLY
Manifold Pressure

4.5”w.c./1.3kPa

10.0”w.c./2.5kPa

Min. Supply Pressure

5.0”w.c./1.3kPa

11.0”w.c./2.8kPa

Max. Supply Pressure 10.0”w.c./1.8kPa

13.0”w.c./3.3kPa

Annual Fuel Utilization Efficiency (AFUE) 72.7%

74.9%

Steady State Efficiency

73.4%

75.6%

It is recommended that the pilot flame be turned off if the appliance will not be in use for an
extended period of time.
This appliance is equipped for use with the fuel type indicated on the rating plate. Fuel conversion kits that
include the necessary parts and instructions are available from your installer, dealer or Harman Stove Co.
This appliance has been certified by OMNI-Test Laboratories, Inc. to ANSI Z21.88-2005 • CSA 2.33-2005
Vented Gas Fireplace Heaters and CAN1-2.17-M91, Gas-Fired Appliances for Use At High Altitudes.
The FireLuxe is approved for installation at elevations up to 2000 feet in the U.S. and 1370 meters (4500
feet) in Canada without change. If your installation is at an elevation greater than these, consult with the
local authority having jurisdiction for gas product installations to determine their specific requirements for
high altitude installations.

28” (71cm)

23 1/4” (59cm)

30 1/2” (77.5cm)

20 1/2”” (52cm)