LIGHTING AND OPERATION

REMOTE CONTROL HANDSET
OPERATION AND PROGRAMMING

Flame Height Adjustment

PILOT FLAME ADJUSTMENT
The pilot flow is factory set to maximum. The pilot
flame should envelope 3/8” to 1/2” of the thermo-
couple. See the illustration above.
The adjustment screw can be reached through the
MAN-knob. See top illustration above.
1. Turn the Man-knob to the ON position.
2. It is now possible to pierce through a film on

the cover with a screwdriver to reach the adjust-
ment screw beneath.

3. Turn the adjustment screw clockwise to de-

crease or counterclockwise to increase pilot
flame.

CORRECT PILOT FLAMES

PILOT FLAME
ADJUSTMENT

CORRECT MAIN BURNER FLAMES

THERMOCOUPLE FLAME

“MAN”