beautypg.com

If you have a problem, Lubrication, Thermal protector – Hoover 4600 User Manual

Page 10: Hoover cleaning performance

background image

10

Lubrication

The cleaner is equipped with bearings
that contain sufficient lubrication for the
life of the cleaner. The addition of lubri-
cant could cause damage.

Therefore,

do not add lubricant to any bearings.

Thermal protector

An internal thermal protector has been
designed into your cleaner to protect it
from overheating.

When the thermal protector activates,
the suction motor will stop running,
however the agitators will continue to
run.

If this happens, proceed as follows:

1. Turn the cleaner OFF and discon-

nect it from the electrical outlet.

2. Check bag. Replace if full.

3. Check final filter for dirt accumula-

tion.

4. Refer to “Clearing blockages”

section.

5.

When the motor cools,

the thermal

protector automatically resets and
cleaning may continue.

If the thermal protector continues to
activate after following the above steps,
your cleaner may need servicing (see
“Service” section).

Hoover Cleaning
Performance

This Hoover Cleaning Performance Sys-
tem is for comparing the relative pro-
gressive performance of

Hoover

uprights only

and not for comparison

with any other brands. The majority of
this rating is based upon the ASTM
International Carpet Cleaning Effective-
ness Test (ASTM Test F608). Other per-
formance factors include Hose Power
(ASTM Test F558), Surface Litter Clean-
ing, Hard Floor Cleaning, Edge Clean-
ing, Cleaning Width, and Air Filtration.

Problem: Powered hand tool brush

roll won’t turn

Possible cause

Possible solution

• Too much pressure being applied to

tool

Continue using tool applying light
pressure.

• Blockage in turbine channel

Remove blockage.

• Broken or worn belt

Replace belt

• Low cleaner suction

Check items under “Cleaner won’t pick

up”.

4. If you have a
problem

If a minor problem occurs, it usually can
be solved quite easily when the cause is
found by using the check list below.

Problem: Cleaner won’t turn on

Possible cause

Possible solution

• Not firmly plugged in

Plug unit in firmly

• No voltage in wall plug

Check fuse or breaker

• Blown fuse or tripped breaker

Replace fuse or reset breaker

• Thermal protector activated

Allow cleaner to cool (this will reset the

thermal protector) (see pg. 10).

• Brush roll shut-off tripped

Turn cleaner OFF, clear brush rolls.

Turn cleaner back ON.

Prob

Problem: Agitator brushes aren’t
turning

Possible cause

Possible solution

• Custom Control™ switch set on

BARE FLOOR position.

Set switch to carpet position.

• Agitators are obstructed.

Clear obstruction.

Problem: Cleaner won’t pick up

Possible cause

Possible solution

• Thermal protector activated

Allow cleaner to cool (this will reset the

thermal protector) (see pg. 10).

• Filter bag full

Change filter bag.

• Incorrect carpet height setting

Move nozzle control knob to lower

setting.

Problem: Cleaner hard to push

Possible cause

Possible solution

• Incorrect carpet height setting

Move nozzle control knob to a
higher setting

Problem: Cleaning tools won’t pick up

Possible cause

Possible solution

• Blockage in hose

Clear blockage.

• Thermal protector activated

Allow cleaner to cool (this will reset the

thermal protector) (see page 10.)