beautypg.com

Troubleshooting, Pressure washer stops suddenly, Water leaking from within the housing – Harbor Freight Tools 2433 User Manual

Page 22

background image

SKU 02433

PAGE 22

For technical questions, please call 1-800-444-3353.

If the steps above do not solve the problem or if the repairs involved are too

complex, contact a qualified technician.

IMPORTANT!

Be CERTAIN to shut off the Pressure Washer, release all pressure in a safe manner, and

disconnect it from power and water before adjusting, cleaning, or repairing the unit.

TROUBLESHOOTING

The thermal safety Switch may be
tripped. Switch the unit off and allow the
unit to rest for 20-30 minutes and retry.

The following points should be
applied to help reduce the
frequency of rest periods:

1.

Use proper operating techniques.
Review the Operating Tips section,
starting on page 16.

2.

Verify that this unit is being supplied
with the correct voltage, see page 14, #2.
Connect the plug to the outlet nearest
the circuit breaker panel and remove any
other loads that may be on the circuit.

3.

If possible, reduce the length of or
eliminate any extension cord used, see
page 9.

PRESSURE WASHER STOPS SUDDENLY

Dry self thoroughly
and check the
circuit breaker on
your household
panel.

Make sure unit is
totally dry, then
press reset button.
If GFCI continues to
trip, contact a
certified electrician.

Check for electrical shorts. If
none are found, reset
breaker.
If breaker continues to trip,
try another circuit or contact
a certified electrician.

BREAKER NOT

TRIPPED

BREAKER TRIPPED

Check whether the power switch is on
and lit.

SWITCH IS LIT

SWITCH IS NOT LIT

Check the indicator on the GFCI power
plug (explained under

Controls and

Features,

#2 on page 12).

Contact qualified
technician.

Contact

qualified

technician.

WATER LEAKING FROM WITHIN THE HOUSING

Seals or gaskets may be worn or damaged.

Leaking water creates a shock hazard;

PROMPTLY

have the unit inspected and

repaired by a qualified technician.

INDICATOR NOT

RED

INDICATOR

APPEARS

RED

UNIT OPERATES

NORMALLY AFTER

RESTING

UNIT DOES NOT

RESTART