Maintenance and servicing – Harbor Freight Tools PACIFIC HYDROSTAR 66351 User Manual
Page 6

SKU 66351
For technical questions, please call 1-800-444-3353.
Page 6
maIntenance and
serVIcIng
Procedures not specifically
explained in this manual
must be performed only by a
qualified technician.
to PreVent
serIous Injury
From accIdental
oPeratIon or electrIc
sHocK:
unplug the sewage Pump
from its electrical outlet
before performing any
accessory change, inspection,
maintenance, and/or cleaning
procedures.
to PreVent serIous
Injury From tool
FaIlure:
do not use damaged
equipment. If abnormal noise
or vibration occurs, have the
problem corrected before
further use.
cleaning, maintenance, and
lubrication
BeFore use and PerIodIcally
1.
tHereaFter, inspect the gen-
eral condition of the Sewage Pump.
Check for loose screws, misalignment
or binding of moving parts, cracked or
broken parts, damaged electrical wir-
ing, and any other condition that may
affect its safe operation.
2.
warnIng! If the supply cord of
this appliance is damaged, it must
be replaced only by a qualified
service technician.
warnIng: this sewage Pump contains
dielectric motor oil for both lubri-
cation and heat transfer. It may be
under pressure because of heat
collection. let the sewage Pump
cool for at least 2 hours before
inspecting, or servicing. this oil
may be dangerous to the environ-
ment. always dispose of used oil
in compliance with all local, state
and Federal rules and regulations.
unclogging the Impeller (24).
Unplug the Sewage Pump, put on
1.
heavy-duty insulated rubber gloves
and ANSI-approved safety goggles.
Remove the discharge hose, or pipe.
2.
Lift Sewage Pump out of water using
3.
the Handle (5).
To unclog the Impeller (24), remove
4.
5 Screws (28) on the Sewage Pump
bottom and remove Base (27).
Flush the Impeller (24) with clean,
5.
lukewarm water.
Reinstall the Impeller (24) and re-
6.
place the Base (27) using the 5
Screws (28).
Using the Handle (5), replace the
7.
Sewage Pump into water in original
position.
Re-thread the discharge pipe, or
8.
hose.
Plug the Sewage Pump back into the
9.
120 Volt, GFCI power outlet.
The Sewage Pump will start auto-
10.
matically.