beautypg.com

Operating instructions – Harbor Freight Tools PACIFIC HYDROSTAR 66351 User Manual

Page 5

background image

SKU 66351

For technical questions, please call 1-800-444-3353.

Page 5

refer to the Assembly Diagram near

the end of this manual.

assemBly

Thread a discharge hose, or pipe

1.

(not supplied) to the orifice on side of

Base (27).
If you use a check-valve (not sup-

2.

plied), mount the check valve hori-

zonally or at 45°. The valve pivot

should be on top. NOTE: If the

check valve should be mounted in a

vertical position, solid waste will tend

to lodge on top of the valve flapper

preventing it from opening.
If using a check-valve, drill a 1/16”

3.

hole in the discharge hose, or pipe 1”

to 2” above the Base (27). The hole

will prevent an air lock in the Mo-

tor (18) both at start up and/or if the

Sewage Pump should lose its prime.
After the check-valve, a (full-port)

4.

gate-valve (not supplied), which will

pass 2” solid waste should be in-

stalled in the system. The gate-valve

allows removal of the Sewage Pump

for cleaning and service.

note: If you do not feel qualified to

completely (and safely) install this

sewage Pump, it is recommended

that you have it installed by a

qualified plumber, or service tech-

nician.

oPeratIng InstructIons

read the entIre ImPortant

saFety InFormatIon section

at the beginning of this manual

including all text under

subheadings therein before set

up or use of this product.

Before operating the Sewage Pump,

1.

put on ANSI-approved safety gog-

gles and other safety gear including

heavy-duty, insulated rubber gloves.

Safety goggles and other safety gear

are sold separately.
Install the Sewage Pump firmly on it’s

2.

Legs and supported by rigid hose, or

pipe discharge fixtures to eliminate

twisting and damage from motor

torque during operation.
After installation, allow the Sew-

3.

age Pump to flood with water before

plugging Power Cord (1) into outlet.

This will help prevent over heating

from running the Motor (18) with no

water resistance moving through the

Sewage Pump. Once this Sewage

Pump is plugged into a 120 Volt GFCI

outlet, the Motor (18) will start auto-

matically.
This Sewage Pump is designed to

4.

transfer waste water in cycles.

Rev 09i