Page 5
refer to the Assembly Diagram near
the end of this manual.
assemBly
Thread a discharge hose, or pipe
1.
(not supplied) to the orifice on side of
Base (27).
If you use a check-valve (not sup-
2.
plied), mount the check valve hori-
zonally or at 45°. The valve pivot
should be on top. NOTE: If the
check valve should be mounted in a
vertical position, solid waste will tend
to lodge on top of the valve flapper
preventing it from opening.
If using a check-valve, drill a 1/16”
3.
hole in the discharge hose, or pipe 1”
to 2” above the Base (27). The hole
will prevent an air lock in the Mo-
tor (18) both at start up and/or if the
Sewage Pump should lose its prime.
After the check-valve, a (full-port)
4.
gate-valve (not supplied), which will
pass 2” solid waste should be in-
stalled in the system. The gate-valve
allows removal of the Sewage Pump
for cleaning and service.
note: If you do not feel qualified to
completely (and safely) install this
sewage Pump, it is recommended
that you have it installed by a
qualified plumber, or service tech-
nician.
oPeratIng InstructIons
read the entIre ImPortant
saFety InFormatIon section
at the beginning of this manual
including all text under
subheadings therein before set
up or use of this product.
Before operating the Sewage Pump,
1.
put on ANSI-approved safety gog-
gles and other safety gear including
heavy-duty, insulated rubber gloves.
Safety goggles and other safety gear
are sold separately.
Install the Sewage Pump firmly on it’s
2.
Legs and supported by rigid hose, or
pipe discharge fixtures to eliminate
twisting and damage from motor
torque during operation.
After installation, allow the Sew-
3.
age Pump to flood with water before
plugging Power Cord (1) into outlet.
This will help prevent over heating
from running the Motor (18) with no
water resistance moving through the
Sewage Pump. Once this Sewage
Pump is plugged into a 120 Volt GFCI
outlet, the Motor (18) will start auto-
matically.
This Sewage Pump is designed to
4.
transfer waste water in cycles.
Rev 09i