main wiring Installation
To install power to the boiler
, first remove the cover on the 4” X 4” junction box located on the back of the unit.
There are several knockout
holes provided for the incoming main power wires.
Also, a knockout hole can be used for the auxiliary output overheat zone (if used).
The minimum recommended circuit is 6
AMP
- 120
VAC - 60 HZ.
This boiler should be the only appliance on the circuit.
This boiler
should never
be power
ed by the use of an extension cord.
The recommended high and low voltages are, 130
V.A.C. 60 Hz maximum high voltage, and 1
13
V.A.C. 60 Hz minimum low voltage.The furnace will
continue to operate at voltages as low as 105
V.A.C. , although it can not be guaranteed that automatic ignition will occur
.
NOTE: If other
sour
ces of electrical
power
ar
e to be used ( such as a generator
) for
normal operation or
emergency
operation, this sour
ce
should be checked
befor
e
installation.
Many generators and inverters
may not supply 120V
.A.C. 60Hz.
power
stable enough to operate