19. motor start/burnback control – Hobart Welding Products OLYMPIC R-115 User Manual
Page 23
OM-193 471 Page 19
2-19. Motor Start/Burnback Control
Ref. 802 310 / 192 653
To change wire feed starting speed
proceed as follows:
Turn Off unit and welding power
source.
Remove wrapper.
1
Motor Board PC1
2
Motor Start Control
Potentiometer R73
Remove protective white rubber
cap before making adjustment.
Adjust potentiometer R73 using a
small nonconductive screwdriver.
Rotate potentiometer clockwise to
increase time it takes the motor to
ramp up to speed.
3
Burnback Potentiometer R42
Remove protective white rubber
cap before making adjustment.
Adjust potentiometer R42 using a
small nonconductive screwdriver.
Rotate potentiometer clockwise to
increase burnback time.
Reinstall wrapper.
Tools Needed:
1/4 in
3
Non-Conductive
2
1
See also other documents in the category Hobart Welding Products Tools:
- XTP (16 pages)
- IRONMAN M-10 (56 pages)
- HANDLER 140 217 694E (48 pages)
- OM-1594 (68 pages)
- DP-3035 (28 pages)
- 250A (32 pages)
- 175 (52 pages)
- OM-947 (48 pages)
- CHAMP 2060 (60 pages)
- 120 (48 pages)
- OM-494 (76 pages)
- 302 (40 pages)
- DP 3035-10 (32 pages)
- CHAMPION 4500 210 597J (52 pages)
- HOOD XVX (20 pages)
- HANDLER 180 (52 pages)
- STICKMATE OM-950 (40 pages)
- 3035-20 (32 pages)
- H-9A Gun (24 pages)
- HANDLER 210 (52 pages)
- OM-948 (24 pages)
- 187 (52 pages)
- AIRFORCE 375 OM-2210 (32 pages)
- ARCSTAR OM-487 (60 pages)
- 300 AC (32 pages)
- Stickmate 205 AC (2 pages)
- AIRFORCE HP-25 TORCH (36 pages)
- 1435 (60 pages)
- AIRFORCE 250A (32 pages)
- 000 OM-945 194 047U (64 pages)
- 000 OM-945 (68 pages)
- CHAMPION OM-493 (56 pages)
- CHAMPION ELITE OM-240 438E (64 pages)
- AIRFORCE OM-230 455D (36 pages)
- SPOOL GUN DP 3035-20 (32 pages)
- OLYMPIC S-62 (36 pages)
- SPOOL GUN 3035-20 (2 pages)
- STICKMATE OM-949 (36 pages)
- HANDLER 210 OM-227 978B (52 pages)
- AIRFORCE OM-928 (32 pages)
- AIRFORCE 700I (40 pages)
- IRONMAN 230 (56 pages)
- HANDLER 210 MVP (56 pages)
- ARCSTAR 280 NT (52 pages)