Hobart Welding Products OLYMPIC R-115 User Manual
Page 22
![background image](/manuals/96262/22/background.png)
OM-193 471 Page 18
2-17. Connection For Welding Power Sources With Hubbell Receptacles
Ref. 802 310 / Ref. 193 749
1
Terminal Block 1T
2
Interconnecting Power Cord
3
Green Lead (Connected To
Ground In Section 2-9)
Connect remaining leads to
terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: No Connection
E: 115 VAC/Contact Closure Lead
Secure strain relief clamp around
cord.
Reinstall and secure wrapper to
unit.
Connect remaining end of cord to
welding power source.
Tools Needed:
1/4 in
1
A
B
C
D
E
2
3
.
Make ground lead connections
according to Section 2-9 before
following this procedure.
2-18. Connection For Miller Welding Power Sources With 14-Socket Receptacle
Ref. 802 310 / Ref. 193 749
1
Terminal Block 1T
2
Interconnecting Power Cord
3
White Lead
4
Black Lead
5
Red Lead
6
Green Lead (Connected To
Ground In Section 2-9)
Connect remaining leads to
terminal block as follows:
A: White Lead (115 VAC/Neutral)
B: Black Lead (115 VAC/Hot)
C: No Connection
D: No Connection
E: Red Lead (115 VAC/Contact
Closure)
Secure strain relief clamp around
cord.
Reinstall and secure wrapper to
unit.
Connect remaining end of cord to
welding power source.
Tools Needed:
1/4 in
1
A
B
C
D
E
2
5
6
4
3
A
J
B
K
I
C L N
H
D M
G
E
F
.
Make ground lead connections
according to Section 2-9 before
following this procedure.