Three phase motor data chart d, Material construction chart e, Minimum wire size chart (gauge) chart f – HP Pressure Booster Pumps 0907 User Manual
Page 3
3
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com
Three Phase Motor Data Chart D
Three Phase† 60/50 Hz 3450/2850 RPM Capacitor Start
HP
Motor
Voltage
Factory
Connected
Motor
Voltage
Service Factor Motor
Amps
Locked Rotor Motor
Amps
Code Letter
230V
460V
230V
460V
3/4
1
1-1/2
2
3
✝✝
208-230/460
208-230/460
208-230/460
208-230/460
208-230/460
230V
230V
230V
230V
230V
3.5
4.5
5.7
7.4
9.8
1.75
2.25
2.85
3.70
4.90
19.0
26.9
33.5
44.0
48.0
9.5
13.5
16.8
22.0
24.0
K
K
K
K
D
✝✝3 HP, 3 Phase motor operable on 60Hz only.
Material
Construction
Chart
E
Component
Standard Models*
Stainless Steel Models
Motor
Rear access - Nema 56J face
Rear access - Nema 56J face
Bearings
Ball-ball, permanently lubricated
Ball-ball, permanently lubricated
Impellers
Noryl with 304 stainless steel bearing insert
Noryl with 304 stainless steel bearing insert
Diffuser
Noryl
Noryl
Diffuser plates
Delrin
Delrin
Pump shaft
416 Stainless steel
304 Stainless steel
Pump shaft coupling
316 Stainless steel
316 Stainless steel
Pump shell
304 Stainless steel
304 Stainless steel
Discharge & inlet casting
Cast iron
304 Stainless steel
O-Rings
Buna-N
Viton
Seal composition
Carbon-silicon carbide, stainless steel spring
and Buna-N
Carbon-silicon carbide, stainless steel spring
and Viton
*Models with powder coated inlet & discharge also available.
Minimum Wire Size Chart (Gauge)
Chart F
Motor
HP
Volts
Phase
Distance In Feet From Motor To Service Panel
Breaker Size
(Amps)
0-50
50-100
100-150
150-200
200-300
Wire Size
1/3
115/230
1
14/14
14/14
14/14
12/14
12/14
15/15
1/2
115/230
1
12/14
12/14
12/14
12/14
10/14
20/15
3/4
115/230
1
12/14
12/14
10/14
10/12
8/12
20/15
1
115/230
1
10/14
10/14
10/12
8/12
6/10
30/15
1
1
/
2
115/230
1
10/12
8/12
6/12
*/10
*/10
30/20
2
115/230
1
10/12
8/12
6/12
*/10
*/10
30/20
3
230
1
10
10
10
10
8
30
3/4
230/460
3
14/14
14/14
14/14
14/14
14/14
15/15
1
230/460
3
14/14
14/14
14/14
14/14
12/14
15/15
1
1
/
2
230/460
3
14/14
14/14
14/14
12/14
12/14
15/15
2
230/460
3
14/14
14/14
14/14
12/14
10/12
15/15
3
230/460
3
14/14
14/14
14/14
12/14
10/12
15/15
(*) Not economical to run in 115V, use 230V.