7-2. Optional Generator Power Receptacles

Y If unit does not have GFCI re-

ceptacles, use GFCI-

protected extension cord.

Combined output of all receptacles

limited to 10 kVA/kW rating of the

generator.
GFCI Receptacle Option
1

120 V 20 A AC GFCI Recep-

tacles GFCI2 and GFCI3

GFCI2 and GFCI3 supply 60 Hz

single-phase power at weld/power

speed. Maximum output from

GFCI2 or GFCI3 is 2.4 kVA/kW. Cir-

cuit breaker protection is the same

as standard receptacles.
If a ground fault is detected, the

GFCI Reset button pops out and

the circuit opens to disconnect the

faulty equipment. Check for

damaged tools, cords, plugs, etc.

connected to the receptacle. Press

button to reset receptacle and

resume operation.

.

At least once a month, run
engine at weld/power speed
and press Test button to verify
GFCI is working properly.

1

7-3. Wiring Optional 240 Volt Plug

120 813-D

The plug can be wired for a 240 V,

2-wire load or a 120/240V, 3-wire

load. See circuit diagram.
1

Plug Wired for 120/240 V,

3-Wire Load

When wired for 120 V loads, each

duplex receptacle shares a load

with one half of 240 V receptacle.
2

Plug Wired for 240 V, 2-Wire

Load

3

Neutral (Silver) Terminal

4

Load 1 (Brass)Terminal

5

Load 2 (Brass) Terminal

6

Ground (Green) Terminal

7

Amperes Available Using

120/240 V Plug

1

2

3

4

5

6

3

4

5

6

240V

240V

120V

120V

*One 240 V load or two 120 V loads.

7

Current Available in Amperes

240 V

Receptacle*

Each 120 V Duplex

Receptacle

V x A = Watts

35
30
25
20
15

0
5

10
15
20

Tools Needed: