Electrical connection – Hoshizaki KM-501MRH User Manual
Page 15
15
4. Electrical Connection
WARNING
This remote condenser unit requires a ground that meets the national and
local electrical code requirements. To prevent possible electrical shock to
individuals or extensive damage to equipment, install a proper ground wire to
the condenser unit.
• This condenser unit must be connected to the fan motor junction box on the icemaker.
• The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.
• Usually an electrical permit and services of a licensed electrician are required.
1) Remove the panel.
2) Remove the junction box cover.
3) Connect the fan motor leads in the junction box of the remote condenser unit to the fan
motor leads in the junction box of the HOSHIZAKI remote air-cooled icemaker.
4) Install a ground wire from the icemaker to the remote condenser unit.
5) Replace the junction box cover and the panel in their correct positions.
Fig. 7