WATER INLET CONNECTIONS









































A standard 120-volt power cord provides the
electrical connection. The unit is designed to
operate on a separate 15-amp circuit.

Inlet Water Line Connection

1

st

production units had a 3/4" BSP

connection directly to the inlet water
valve. (DO not connect with 3/4" FIP)

Fitting (4A3207-01) and gasket

413854-01 were used from May
through July production. (Through
August on the AM-100BAE and AM-
150 BAF)

Fitting (4A3240-01) and

gasket

413854-01 were added in August 03
on the AM-50BAE and September 03
on the AM-100BAE and AM-
150BAF.

If no fitting is included, order either fitting
/gasket above or use 3/4" hose type fitting to
make this connection.

A minimum 3/8” water line is required for
proper operation.

Drain line connection

The drain connection for the AM-50 was
5/8” I.D. hose until April of 2004 and was
located on the left rear of the unit. A
standard 3/4” male insert fitting can be used
to connect this drain. From May 2004 the
drain fitting is 1/2” FPT. A minimum 1/2”
I.D. vented drain is required when making
this connection.

The drain for the AM-100 and AM-150 is a
3/4” MPT.

Since the unit will likely be enclosed, it is
recommended to use flexible, supply and
drain connections. This will allow easy
removal if service is necessary.

DRAIN CONNECTIONS

4A3240-01

1/2” FPT

4A3207-01

3/8” Male flare

(AM-50 through April

2004)

(AM-100 & AM-150)

AM-50 from May 2004

1/2” FPT

3/4” MPT

5/8” I.D. rubber hose