Maintenance – Harbor Freight Tools 98342 User Manual
Page 4
SKU 98342
For technical questions, please call 1-800-444-3353.
Page 4
MAInTEnAncE
TO PREVEnT
SERIOUS InjURy
FROM AccIdEnTAL
OPERATIOn:
Unplug the Pump from its
electrical outlet before
performing any inspection,
maintenance, or cleaning
procedures.
If the pump is moved during op-
eration, flush it out with clean water after
every use.
Quarterly Maintenance
The below maintenance must be per-
formed at least once every 3 months under
optimal conditions. For frequent use, or
dirty areas, more frequent maintenance is
required.
Clean sludge and debris from the bot-
1.
tom of the shaft.
Rinse the housing off with clean wa-
2.
ter.
Clean fibers from inside the pump
3.
housing with a pressure washer (not
included).
If the pump housing cannot be
4.
cleaned from the outside, it must be
thoroughly cleaned.
Make sure the
power cord is unplugged before
maintenance. Dismantle the bottom
part of the pump as follows:
FIgURE B
IMPELLER
(14)
FILTER
(11)
a. Remove the Filter (11) from the
pump case.
Clean the impeller with clean water.
b.
To prevent damage, do not rest the
c.
pump on the impeller or pry against
the impeller.
Reassemble in reverse order.
d.