beautypg.com

Warning, Specifications, Caution – Harbor Freight Tools 98342 User Manual

Page 2: Fluid type

background image

SKU 98342

For technical questions, please call 1-800-444-3353.

Page 2

Before start-up, note the following:

The pump can be connected to any

shock-proof plug which has been installed

according to regulations. The plug must

have a supply voltage of 115 V~ at 60 Hz.

cAUTIOn

This pump has been evaluated for

use with water only.

WARnIng

IMPORTAnT! For your own safety –

before starting to run the pump, please

have the following items checked by an

expert:

Risk of electric shock – This pump is

1.

supplied with a grounding conductor

and grounding-type attachment plug.

To reduce the risk of electric shock,

connect only to a properly grounded,

grounding-type receptacle.
Risk of electric shock – This pump

2.

has not been investigated for use in

swimming pool areas.
The electrical connections must be

3.

protected from moisture.
If there is danger of flooding, the

4.

electrical connections must be taken

to higher ground.
Circulation of caustic fluids, as well

5.

as the circulation of abrasive materi-

als, must be avoided at all costs.
The pump must be protected from

6.

frost.
The pump must be protected from

7.

running dry.

Access by children should also be

8.

prevented with appropriate mea-

sures.
WARNING: Handling the Power Cord

9.

on this product will expose you to

lead, a chemical known to the State

of California to cause cancer, and

birth defects or other reproductive

harm. Wash hands after handling.

(California Health & Safety Code §

25249.5, et seq.)
The warnings, precautions, and in-

10.

structions discussed in this instruction

manual cannot cover all possible con-

ditions and situations that may occur.

It must be understood by the operator

that common sense and caution are

factors which cannot be built into this

product, but must be supplied by the

operator.

Fluid Type

The Pump is designed for use with

water with a maximum temperature of 95°

F (35°C). Do not use the pump for other

fluids, especially not fuels, cleaning fluids,

or other chemical products.

SPEcIFIcATIOnS

Pump Applications

Removes Clear Water Down to

1/8” of Surface

Electrical

Requirements

115 V~ / 60 Hz / 1/4 HP

2.6 A (Start) / 2.5 A (Run)

Power Cord

18AWG X 3C - SJTW

Maximum Capacity

1400 GPH (Approx. 23 GPM)

Maximum Delivery Height 26.3 Ft.

Discharge Size

1” Pipe with 3/4”-11.5 TPI Garden

Hose Adapter