OPeRating instRuCtiOns
Read the entiRe iMPORtant
saFetY inFORMatiOn
section at the beginning of this
manual including all text under
subheadings therein before set
up or use of this product.
Close the Drain (9) completely.
1.
Turn the Tool Pressure Regulator
2.
(6) counterclockwise until it is fully
closed.
Pull the ring on the Safety Valve (3)
3.
to check that it operates properly.
Attach the Air Hose (20) to the air
4.
outlet on the Regulator (6). Connect
the other end of the air hose to the air
inlet of the tool. Other components,
such as a connector and quick cou-
pler, will make operation more effi-
cient, but are not required.
note: If inflating tires or other objects,
connect the Air Hose (20) to the Infla-
tion Chuck (21). Do not overinflate
any object.
Plug the Power Cord/Plug (7) into the
5.
nearest 120 volt, grounded, electrical
outlet.
Turn the Power Switch (19) to its
6.
autO or | position.
Observe the Tank Pressure Gauge
7.
(2), and allow the air pressure in the
Tank (14) to build up to
70 Psi.
Observe the Tool Pressure Gauge
8.
(2A), while turning the Tool Pressure
Regulator clockwise to increase pres-
sure up to the desired level.
WaRning! do not exceed the tool’s
maximum air pressure.
the air Compressor is now ready
9.
to use. When finished using the Air
Compressor, turn the Power Switch
(19) to its
OFF or
O
position. Then,
unplug the Air Compressor from its
electrical outlet.
Turn the Tool Pressure Regulator
10.
(6) counterclockwise until it is fully
closed.
Pull the ring on the Safety Valve (3)
11.
to relieve all remaining air pressure in
the Tank.
Activate the tool in a safe manner
12.
to release air pressure from the air
hose. Then, disconnect the air hose
from the tool, and store the compres-
sor in a safe, dry location.