haier PRCS25SD User Manual
Page 24

Performance Data Sheet For Filter Model 0060820860
Using Replacement Cartridge 0060218743
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below
.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 42 and 53.
System tested and certified by NSF Internationa in Model 0060820860 against NSF/ANSI Standard 53 for th
e
reduction of
Asbestos,
Atrazine, Benozene, Cyst, Carbofuran, Lead, Lindane, Mercury
, p-Dichlorbenzene,
Toxaphene and
T
urbidity and against Standard NSF/ANSI Standard 42 for the reduction of Chlorine
Ta
ste
and Odor; Nominal Particulate Class 1.
Note that while testing was performed under standard
laboratory conditions, actual performance may vary
.
To
a capacity of 750 gallons (2839 liters).
Cysts*
T
urbidity
Asbestos
Lead @ pH 6.5
Lead @ pH 8.5
Mercury @ pH 6.5
Mercury @ pH 8.5
Atrazine
Benzene
Carbofuran
p-Dichlorobenzen
Lindane
Toxaphene
Pariculate
Class 1 Particle size: >0.5 to < 1 um
Chlorine taste and odor
166500
10.7
155 MF/L
0.153
0.150
0.006
0.006
0.009
0.014
0.081
0.208
0.002
0.015
5700000
1.9
1
0.31
<1 MF/L
<0.001
<0.001
0.0003
0.0008
<0.002
0.0006
<0.001
<0.0005
0.000025
<0.001
30583
0.05
99.99
97.09
<99.99
99.35
99.33
95.70
86.22
76.99
95.71
98.74
99.76
98.72
92.97
99.52
97.3
>99.95
%
0.5 NTU
99
%
0.01
0,01
0.002
0.002
0.003
0.005
0.04
0.075
0.0002
0.003
≥85
%
≥50
%
1
0.49
<1 MF/L
<0.001
<0.001
0.0005
0.0015
<0.002
0.001
1
<0.001
<0.0005
0.00007
<0.001
6900
0.6
99.99
95.42
99.99
99.34
99.33
91.66
75.00
77.78
92.14
98.46
99.76
96.5
91.67
98,94
96,84
Minimum 50,000/L
11
+ 1 NTU
10
7
to 10
8
fibers/L,
fibers < than 10um in length
0.15 mg/L
+10
%
0.15 mg/L
+10
%
0.006 mg/L
±10
%
0.006 mg/L
±10
%
0.009 mg/L
±10
%
0.015 mg/L
±10
%
0.08 mg/L
±10
%
0.225 mg/L
±10
%
0.002 mg/L
±10
%
0.015±10
%
A
t l
ea
st
1
0,
00
0
pa
rt
ic
le
s/
m
l
2.0 mg/L± 10
%
A
verage
Influent
Concentration
Substance
Influent Challenge
Concentration mg/L
Product W
ater
Concentration
A
verage %
Reduction
Maximum Permissible
Product W
ater
Concentration
Mac
Ef
fluent
Min %
Reduction
NSF
Test
* Based on the use of Cryptosporium parvum oocysts
Application Guidelines/W
ater Supply Parametersagua
W
ater Pressure
W
ater
Temperature*
Service Flow
Systems must be installed and operated in accordance with
manufacturer
’s
recommended procedures and guidelines.
Change filter at least every 6 9 months.
Flush new filter for 5 minutes
See warranty card for complete details.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the
system.
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Entire System (excluding disposable cartridges) is warrantied for a period of one year
. Disposable cartridges
are warrantied for defects in material and workmanship onl
y.
Service life of disposable filter cartridges varies
with local water conditions and is thus now warrantied.
For estimated costs of replacement
elements please visit your local appliance dealer
or parts distributor
.
Manufactured by: