beautypg.com

Installation procedures, Caution – haier AC142XCERA User Manual

Page 17

background image

15

Installation Procedures

ELECTRICAL WIRING

1. INDOOR UNIT SIDE

(1) Remove the electric component box.

(2) Pull out the electric component box.

(3) Remove the electric component box cover.

Remove the three tapping screws.

(1) Remove the cord clamp.

(2) Process the end of the connection cords to the

dimensions shown in Fig.34.

(3) Connect the end of the connection cord fully into the

terminal block.

(4) Wiring

(4) Fasten the connection cord with a cord clamp.

(5) Fasten the end of the connection cord with the

screw.

Be careful not to pinch the lead wires between the

electric component box and base.

CAUTION

(1) Match the terminal block numbers and connection

cord colors with those of the outdoor unit.

Erroneous wiring may cause burning of the electric

parts.

(2) Connect the connection cords firmly to the terminal

block. Imperfect installation may cause a fire.

(3) Always fasten the outside covering of the connection

cord with the cord clamp.(If the insulator is chafed,

electric leakage may occur.)

(4) Always connect the ground wire.

Do not remove the screws. If the screws

are removed, the electric component box

will fall.

Fig. 26

Electric component box

Remove the four tapping

screws.

Fig. 27

Electric component box

CAUTION

Fig.28

Electric component box

Fig. 29

Base

Electric component box cover

CAUTION