Installation Procedures

HOW TO CONNECT WIRING TO THE TERMINALS

A. For solid core wiring (or F-cable)(Fig.24A)

(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the

exposed solid wire.

(2) Using a screwdriver, remove the terminal screw(s) on the terminal board.

(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.

(4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal

screw using a screw driver.

B. For strand wiring(Fig.24B)

(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the

exposed strand wiring.

(2) Using a screwdriver, remove the terminal screw(s)on the terminal board.

(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.

(4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.

After passing the connection cord and power cable through the insulation tube, fasten it with the cord

clamp, as shown in Fig.25

HOW TO FIXED CONNECTION CORD AND POWER CABLE AT
THE CORD CLAMP

14

Fig. 25

Insulation tube

Cord clamp

Use VW-1, 0.5 to 1.0 mm thick, PVC tube as the insulation tube.

Fig. 24

Insulation

Strip 25mm

Loop

A. Solid wire

Terminal
board

Screw with
special washer

Round
terminal

Wire

Screw with
special washer

Round
terminal

Wire

Strip 10mm

Round
terminal

B. Strand wire