HP PROLIANT 56976839 User Manual
Page 6
Issue:
Install Shield Error 1607/1628 during Service Release installation
Description
Installation error 1607: Unable to install Install Shield
Scripting Runtime
and/or 1628: failed to complete
installation
may be reported during installation of the Service Release. This
error can occur for various reasons, the most prevalent being a driver did not
exit properly when the Service Release is run the first time. This issue is currently
under investigation.
Workaround Run the Service Release again after ensuring that no instances of the processes
named msiexec.exe, setup.exe, or idriver.exe are running.
Issue:
User intervention required during installation of SMS v2.02 on HP ProLiant DL100 G2 servers
with the IMB v3.0 driver
Description
During installation of the Server Management System v2.02 on DL100 G2 servers,
the IMB v3.0 driver sometimes displays a security warning stating the driver does
not have digital signature.
Workaround Accepting the warning message by clicking Continue proceeds with the installation
without any issues.
Issue:
Some information in the Service Release may appear as English instead of the selected language
Description
During installation of the Service Release, some screens may display text as English
instead of the selected language.
Workaround This issue will be corrected in the next Service Release.
Issue:
For HP StorageWorks NAS servers and HP ProLiant Storage Servers with mirrored OS drives
(such as the ML110 G2 Express model), the OS drive re-mirroring fix offered in previous Service
Releases has been removed
Description
The OS drive re-mirroring fix, which ensures that both disks are bootable in the
event of a failure of a drive, has been removed in order to preclude a condition
where the ML110 G2 Express Storage Server (Japanese model) fails to boot from
mirrored OS drives.
Workaround To update the Service Release 6.6 patch for these servers, manually switch to the
mirrored OS and perform the Service Release installation.
Issue:
The HP Storage Server Management console may not be available after installing the Service
Release
Description
The HP Storage Server Management console may not be available after installing
the Service Release for some HP ProLiant Storage Servers with the HP Storage
Server R2 Localization DVD — Windows Multilingual User Interface (MUI) Pack
installed.
Workaround
Using Windows Add or Remove Programs, remove the HP Storage Server
Management Service. Run the Service Release installation again and install the
HP Storage Server Management console component.
Issue:
Web UI 5.6.2 is not installed with Service Release 6.6
Description
On StorageWorks NAS products, the Web UI 5.6.2 patch is not installed with
Service Release 6.6.
Workaround
The Web UI 5.6.2 patch is copied to the C:\hpnas\components\WE-
BUI_5.6.2_Update folder. If not installed by using the HP Service Release 6.6
Wizard, the patch must be installed manually.
6