beautypg.com

Henny Penny TROUBLESHOOTING HHC-990 User Manual

Page 4

background image

Model HHC-990

5-2. ERROR CODES AND
WARNINGS (Continued)

“E-41 SYSTEM DATA LOST”

• Memory scrambled

“E-46 DATA SAVE FAILED”

• Memory scrambled

“E-80 VENT STUCK OR

Vent on rear of module

BAD SWITCH”

stuck or faulty vent
activation switch

“PLEASE DE-LIME

• Water pan needs

WATER PAN”

cleaned

“WATER LEVEL LOW, PLEASE” Water pan low on water

or empty

303

4-8

• Turn switch to OFF position, then back to

ON; if the display shows “E-41”, the
control should be re-initialized (see Pro-
gramming Section); if “E-41”persists, have
PC board replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-46”, the
control should be re-initialized (see Pro-
gramming Section); if “E-46”persists, have
PC board replaced

• Check vent on rear of module for obstruc-

tions, or have vent activation switch
replaced

• Follow the weekly cleaning procedures;

this warning will not shut down the heat
or humidity; if “PLEASE DE-LIME
WATER PAN” persists, have PC board
replaced

• Fill water pan, in bottom of unit, to the

maximum water fill mark; this warning
won’t shut down the heat or humidity

Display

Cause

Panel Board Correction