Henny Penny TROUBLESHOOTING HHC-990 User Manual

Page 2

background image

Model HHC-990

303

4-7

5-2. ERROR CODES AND

The display shows the following error codes and warnings when a

WARNINGS

fault is detected, along with an alarm sound. Both the heat and
humidity systems shut down, except when specified otherwise.

Display

Cause

Panel Board Correction

“E-4

CPU TOO HOT”

• Control board too hot;

unit overheating or
louvers clogged

“E-5

AIR TEMP TOO HOT”

• Faulty relay, PC board,

or air probe

“E-54A CPU TEMP SENSOR

• Faulty PC board

OPEN”

“E-54B CPU TEMP SENSOR

• Faulty PC board

SHORTED”

“E-6A

AIR TEMP SENSOR

• Faulty air probe

FAILED OPEN”

• Turn switch to OFF position, then back to

ON; if display still shows “E-4”, the PC
board is getting too hot; clean louvers and
check cooling fan; if cooling fan is not
working, have it replaced; once panel
cools down, the controls should return to
normal; if “E-4” persists, have the PC
board replaced

• Turn switch to OFF position, then back to

ON; if display shows “E-5”, the heating
circuits and temperature probe should be
checked; once the unit cools down, the
controls should return to normal; if “E-5”
persists, have the PC board replaced

• Turn switch to OFF position, then back to

ON; if display shows “E-54A”, the
control should be re-initialized (see Pro-
gramming Section); if the error code
persists, have PC board replaced

• Turn switch to OFF position, then back to

ON; if display shows “E-54B”, the
control should be re-initialized (see Pro-
gramming Section); if the error code
persists, have PC board replaced

• Turn switch to OFF position, then back to

ON; if the display shows “E-6”, the
temperature probe should be checked;
once the temperature probe is repaired, or
replaced, the controls should return to
normal; if “E-6” persists, have the PC
board replaced