Mode ii setting chart – Hague Quality Water Intl 63MAQ User Manual
Page 15

Mode II Setting Chart
60 SERIES
63MAQ
63BEQ
*
63MXQ
63MDQ
**
62AMQ
62APQ
** .***
62AKQ
**
62AJQ
****
Mode 2
YES
YES
YES
NO
YES
NO
NO
YES
Capacity
As
As
As
--
As
—
—
As
required
required
required
required
required
96 hour regeneration (If
YES OR
YES OR
YES OR
YES OR
—
—
YES OR
Iron present – yes)
•
NO
NO
NO
NO
NO
#1 SALT SETTING
Backwash 1 (minutes)
1
1
1 •
—
2
•
--
'–
-`
Brine rinse (minutes)
7
7
7
—
7
—
--
--
Backwash 2 (minutes)
3
3
3
--
2
—
–'
—
Capacity
fa. salt lbs.
5,850
1 lb.
5,850
1 lb.
9,360
1.6 lb.
—
5,850
1 lb.
—
—
—
#2 SALT SETTING
Backwash 1 (minutes)
1
1
1 •
—
2 •
—
—
7 •
Brine rinse (minutes)
12
12
19
—
12
12
Backwash 2 (minutes)
3
3
3
—
2
—
--
2
Capacity
salt tbs.
13,890
2.7 lbs.
13,890
2.7 lbs.
21,680
4.2 lbs.
—
13,890
2.7 lbs.
—
—
13,890
2.7 lbs.
#3 SALT SETTING
Backwash 1 (minutes)
1
1
Itt
—
2tt
—
—
7
Brine rinse (minutes)
30
30
47
—
30
—
—
30
Backwash 2 (minutes)
3
3
3
—
2
—
--
2
Capacity
( salt lbs.
28,730
6.2 lbs.
28,730
6.2 lbs.
44,840
9.6 lbs.
—
28,730
6.2 lbs.
—
—
28,730
lbs.
#4 SALT SETTING
Backwash 1 (minutes)
1
1
It t
—
4tt
--
—
7
Brine rinse (minutes)
45
45
60
45
—
—
45
Backwash 2 (minutes)
3
3
3
—
2
--
--'
2
Capacity
(aa
salt tbs.
35,300
9.3 lbs.
35,300
9.3 lbs.
55,090
14.4 lbs.
—
35,300
9.3 lbs.
—
—
35,300
9.3 lbs.
*Municipally supplied chlorinated water only.
**NA, see Mode 1 Setting Chart.
***Unit has no backwash flow control button or retainer. Must have a minimum of 7 gpm@30 psi available for proper backwash.
****Calcite will add additional hardness to water before softening.
*If iron is present in water supply, use salt setting #3 or #4.
ttlf iron is present in the water supply, set #1 backwash to 7 minutes.
15