F4,11gineering specifications, 60 series – Hague Quality Water Intl 63MAQ User Manual
Page 13

F4,11gineering Specifications
60 SERIES
63MAQ 63BEQ* 63MXQ
63MDQ 62AMQ **62APQ*** 62AKQ 62AJQ****
Tannin (ppm)
0
0
0
0-2
0
0
0
0
Sulfur (ppm) - SulfurStat
0
0
0
0
0
0-5**
0
0
Iron (ppm) - ferrous - clear water •
0
0
12
0
12
2-12**
15
5
Maximum Compensated Hardness
90
90
110
90tt
90
90
90
60
Maximum Chlorine (ppm)
1
3
0
0
0
0
0
0
Minimum pH
NA
NA
7
7
7
7
7
6.3
Filtration - nominal rating (microns)
20
25
20
20
20
20
20
20
#1 Salt - 5850 grains per lb of salt (Ibs./capacity)
1/5,850
1/5,850
1.6/9,360
NA
1/5,850
NA
NA
NA
#2 Salt - 5163 grains per lb of salt (Ibs./capacity)
2.7/13,890 2.7/13,890 4.2 /21,680
NA
2.7/13,890
NA
NA
2.7/13,890
#3 Salt - 4679 grains per lb of salt (Ibs./capacity)
6.2/28,730 6.2/28,730
9.6/44,840
8.5/28,730
6.2/28,730 6.2/28,730
6.2/28,730 6.2/28,730
#4 Salt - 3828 grains per lb of salt (Ibs./capacity)
9.3/35,300 9.3/35,300 14.4/55,090 10.7/35,300
9.3/35,300 9.3/35,300
9.3/35,300 9.3/35,300
Media Amount Compartment #1
1.5 lbs.
2.0 lbs.
1.5 lbs.
1.5 lbs.
NA
NA
NA
NA
Media Amount Compartment #2
Empty
.4 cu.ft.
.6 cu.ft.
.3 cu.ft.
6 Ibs.
27 Ibs.
.4 cuft.
.4
cu.ft.
Media Amount Compartment #3
1.06 cu.ft.
1.06
cu.ft.
1.06 cu.ft.
1.06 cu.ft
1.06
cuff.
1.06 cu.ft.
1.06
cuff.
1.06 cu.ft.
Drain Line Flow Control (gpm)@ min. water presure
2.41'
3t
2.4t
2.4t
5t
Empty***t
7t
7t
Brine Line Flow Control Refill (gpm)
.5
.5
.5
.5
.5
.5
.5
.5
Water Pressure (min-max psi)
20-120
20-120
20-120
20-120
20-120
30-120
30-120
30-120
Flow Rate @ 25 psi drop
19.5
19.5
17
17
23
19.6
19.6
20.5
Flow Rate @ 15 psi drop#
11
13
10.5
10.5
11.2
10.6
10.6
12.5
Pressure Drop @ Flow Rate Of 4 gpm
6.5 psi
8.5 psi
8.5 psi
8.5 psi
3.2 psi
6 psi
6 psi
7 psi
(#1 Salt setting) total length of reg. Min / gal
12/13.5
12/16
12/13.5
NA
12/24
NA
NA
NA
(#2 Salt setting) total length of reg. Min / gal
18/16.5
18/19
26/20.5
NA
18/27
NA
NA
23/70
(#3 Salt setting) total length of reg. Min / gal
38/26.5
38/29.5
58/36.5
47/31
38/37
44/80
44/80
44/80
(#4 Salt setting) total length of reg. Min / gal
56/35.5
56/38
74/44.5
64/39.5
58/56
61/89
61/89
61/89
Shipping weight (Ibs.)
135
152
168
152
140
167
160
180
Bacteriostatic - KDF® Process Media - Listed
With The U.S. EPA As A Bacteriostatic Device.
U.S. EPA #54369-OH-001
YES
YES
YES
YES
YES
YES
YES
YES
Valve Inlet/Outlet 1"
Drain Line (Minimum ID.)
%Y "
Water Temperature (Min-Max) 40-120 °F
Height (inches) 38-1/4"
Floor Space (inches) 15" x 30"
Salt storage capacity: 200 Ibs, 90kg
Brine & Rinse total: .65 gpm
Brine Draw: .25 gpm
Rinse: .4 gpm
Electrical rating: 115V, 60 cycle.
Iron Reduction To .3 ppm Or Less.
When Adding Media In The Field, Check For Proper Settings
(See Specifications, Above.)
Regeneration Every 96 Hours Is Required When Iron Is
Present In The Raw Water Supply. Use Salt Setting #3 Or #4.
*Municipally Supplied Chlorinated Water Only.
**Must Have A Minimum of 2 ppm Iron and a Minimum
of 200 ppm TDS.
***This model Has No Backwash Flow Control Button Or
Retainer. Must Have A Minimum Of 7 gpm @ 30 psi
Available For Proper Backwash.
****Calcite Will Add Additional Hardness To Water Before
Softening.
tRate Of Flow Must Be Verified At The End Of
%Y
"
ID
Drain Line.
tt
An
y Hardness Over 10 gpg Will Increase The Chance
Of Calcium Carbonate Precipitation. As The
Hardness Increases So Does The Chance Of This
Precipitation. Must Use Citric Acid to Regenerate
Along With Salt.
13