beautypg.com

Warming operation, Care and maintenance – haier AU092AABHA User Manual

Page 11

background image

10

"HOT KEEP"is operated in the following cases.

When heating is started:

In order to prevent blowing out of cool wind, the indoor unit fan stopped

according to the room temperature which heating operation is started. Wait

for approx. 2 to 3 minute, and the operation will be automatically changed

to the ordinary heating mode.

Defrosting operation (in the heating mode):

When it is liable to frost. the heating operation is stopped automatically

for 5 to 12 minutes once per approx. one hour, and defrosting is operated.

After defrosting is completed, operation mode is automatically changed

to ordinary heating operation.

When the room thermostat is actuated:

When room temperature increases and room temperature controller actu-

ates, the fan speed is automatically changed to stop under low temperature

condition of indoor heat exchanger. When room temperature decreases,

air conditioner automatically changes over to ordinary heating operation.

WARMING OPERATION

Heat pump type warming

Defrosting operation

Atmospheric temperature and warming capacity

Period of warm-up

With the heat pump type warming, the mechanism of heat pump that concentrate heat of

outdoor air with the help of refrigerant to warm the indoor space, is utilized.

When a room is warmed with a heat pump type air conditioner, frost accumulates on the

heat exchanger of outdoor unit along with the drop of indoor temperature. Since the

accumulated frost reduces the effect of warming, it is necessery to automatically switch

the operation to the defrosting mode. During the defrosting operation, heating operation

is interrupted.

Warming capacity of heat pump type air conditioner decreases along with the

drop of outdoor temperature.

When the warming capacity is not sufficient, it is

recommended to use another heating implement.

Since the heat pump type air conditioner employs a method

to circulate warm winds to warm the entire space of a room,

it takes time before the room temperature rises.

It is recommendable to start the operation a little earlier in a very cold morning.