4 .3 projector management using snmp – Hitachi CP-X308 User Manual
Page 91
9
4 . Management with Web browser software
4 .3 Projector Management using SNMP
The SNMP (Simple Network Management Protocol) enables to manage the
projector information, which is a failure or warning status, from the computer on
the network. The SNMP management software will be required on the computer
to use this function.
• It is recommended that SNMP functions be carried out by a network
administrator.
• SNMP management software must be installed on the computer to monitor
the projector via SNMP.
NOTE
SNMP Settings (71)
Configure the following items via a web browser to use SNMP.
Example: If the IP address of the projector is set to 192.168.1.10:
1) Enter
“http://192.168.1.10/” into the address bar of the web browser.
2) Enter the Administrator ID and Password and click
[Logon].
3) Click
[Port Settings] on the main menu.
4) Click
[Enable] check box to open the SNMP Port. Set the IP address to send
the SNMP trap to when a Failure/Warning occurs.
5) Click
[Security Settings] on the main menu.
6) Click
[SNMP] and set the community name on the screen that is displayed.
7) Configure the settings for Trap transmission of Failures/Warnings. Click
[Alert Settings] on the main menu and select the Failure/Warning item to be
configured.
8) Click
[Enable] check box to send out the SNMP trap for Failures/Warnings.
Clear
[Enable] check box when SNMP trap transmission is not required.
9) Click
[Apply] button to save the settings.