Harbor Freight Tools 34951 User Manual
Page 5
Page 5
SKU 34951
for technical questions, please call 1-800-444-3353.
grOunDeD tOOls: tOOls witH tHree prOng plugs
Tools marked with “Grounding Required” have a three wire cord and three prong
grounding plug. The plug must be connected to a properly grounded outlet. If the
tool should electrically malfunction or break down, grounding provides a low resis-
tance path to carry electricity away from the user, reducing the risk of electric shock.
(see 3-prong plug and Outlet.)
The grounding prong in the plug is connected through the green wire inside the
cord to the grounding system in the tool. The green wire in the cord must be the
only wire connected to the tool’s grounding system and must never be attached to
an electrically “live” terminal.
(see 3-prong plug and Outlet.)
Your tool must be plugged into an appropriate outlet, properly installed and grounded
in accordance with all codes and ordinances. The plug and outlet should look like
those in the following illustration.
(see 3-prong plug and Outlet.)
3-prong plug and Outlet
Outlets for 2-prong plug
DOuBle insulateD tOOls: tOOls witH twO prOng plugs
Tools marked “Double Insulated” do not require grounding. They have a special
double insulation system which satisfies OSHA requirements and complies with
the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard
Association, and the National Electrical Code.
(see Outlets for 2-prong plug.)
Double insulated tools may be used in either of the 120 volt outlets shown in the
preceding illustration.
(see Outlets for 2-prong plug.)
extensiOn cOrDs
Grounded tools require a three wire extension cord. Double Insulated tools can
use either a two or three wire extension cord.
As the distance from the supply outlet increases, you must use a heavier gauge
extension cord. Using extension cords with inadequately sized wire causes a seri-
ous drop in voltage, resulting in loss of power and possible tool damage.
(see table a.)
1.
2.
3.
1.
2.
1.
2.