Unpacking, Assembly, Operation – Harbor Freight Tools CAST IRON VERTICAL 93271 User Manual
Page 5
SKU 93271
For technical questions, please call 1-800-444-3353.
PAGE 5
unPaCKInG
When unpacking, make sure the item is intact and undamaged. If any parts are
missing or broken, please call Harbor Freight Tools at the number shown on the cover of
this manual as soon as possible.
Find the bag/box that contains all hardware for mounting the parts that are shipped
detached.
assEMBlY
Before use, thread the Muffler/Air Filter (7A) assembly into the Cylinder Case (2B).
oPEratIon
note: For additional references to the parts listed below, refer to the assembly dia-
grams on pages 10, and 11.
to Check the oil level:
FIGurE a
oil Breather (14B)
oil Window (20B)
Front Cover (18B)
1. The Oil Window (20B) is used to determine if oil is needed. The oil level should
always be at the maximum level (red line on the Oil Window).
(see Figure a, and
assy. diagram B.)
unscrew
2.
(do not pull) the Oil Breather (14B) out.
(see Figure a.)
If necessary, add a
3.
premium quality, 30-weight, non-detergent oil into the Oil Fill
Hole until the level of oil reaches the maximum level as indicated on the Oil Win-
dow (20B). The optimal capacity of the oil reservoir is 30 ounces. Do not overfill.
Then thread the Oil Breather back into the Oil Fill Hole, being careful not to strip
the plastic threads.
rEV 08l