For technical questions, please call 1-800-444-3353.

SKU 69243

Specifications

Laser Range

Projects Up to 40 ft.

Max. Tripod Height

48”

Self Leveling Range 6°
Batteries

(2) ‘AA’ (included)

WARNING

To prevent serious injury and blindness:

Do not use included goggles for eye

protection. Read manual before use.

LASER LIGHT

AVOID DIRECT EYE EXPOSURE

Max. Output: <5mW,

Wavelength: 650 nm ±10 nm

CLASS IIIa LASER PRODUCT

This product complies with 21 CFR 1040.10 and 1040.11

Diode Mfr.: Sean & Stephen Corp.

4F, NO3, Lane 335, Sec 4, Hsin-Yi Rd., Taipen, China

Manufacture Date: ___________, _______

11k

Assembly

Read the ENTIRE IMPORTANT

SAFETY INFORMATION section at the

beginning of this manual including

all text under subheadings therein

before set up or use of this product.

TO PREVENT SERIOUS INJURY

FROM ACCIDENTAL OPERATION:

Turn Line Buttons off before adjusting Laser Level.

Note: For additional information regarding the

parts listed in the following pages, refer to the

Assembly Diagram near the end of this manual.

1. Remove the tripod from the case.

2. Open tripod’s legs and adjust positioning

of each leg until base is level. Use bubble

level in tripod base as a guide.

3. Remove the Laser Level from the case.

4. Install batteries, making sure to align

batteries according to indicated polarity.

5. Attach the Laser to the tripod base. Do this by

threading the bolt at the top of the tripod through the

holes at the center of the Laser Level’s lower base.

6. Level the Laser by using the tri-brack

adjustment screws until the bubbles

are centered on the two levels.

7. Push the Pendulum Lock to the right to

free the pendulum. See Figure 1.

Figure 1

Pendulum

Lock

8. Turn on the Laser. Allow the laser lines to

stabilize for 4 to 6 seconds before starting

any measuring or leveling tasks.

9. To disassemble and store, move the

pendulum lock to the left (see Figure 1) and

follow the above directions in reverse.

NOTICE: If the pendulum lock is not engaged

before movement, the level may be damaged.

REV 10k