General Operating Instructions

1.

WARNING! Use only 3/8” Drive

Impact type sockets (sold separately).

2. If an automatic oiler is not used, add

a few drops of Pneumatic Tool Oil

to the airline connection before use.

Add a few drops more after each

hour of continual use.

3. Push and snap the socket (not

included) onto the Anvil (31).

4. Slide Reverse Valve (9) to the

left

for clockwise (forward) rotation.

NOTE: This is a sliding valve that is

connected to Regulator Knob (12).

5. Place the socket over the nut you

wish to tighten.

6. Grip tool firmly with both hands and

gently squeeze Trigger (14).

7. Adjust air flow by turning Air

Regulator Knob from positions 1

through 5. Match up desired number

setting with the recessed dimple.

Position 1 allows the lowest amount

of air flow, and Position 5 the highest.

8. If the tool requires more force to

accomplish task, verify that the tool

receives sufficient, unobstructed

airflow (CFM) and increase the

pressure (PSI) output of the regulator

up to the maximum air pressure

rating of this tool.

9.

CAUTION! TO PREVENT TOOL

AND ACCESSORY FAILURE,

RESULTING IN INJURY:

Do not exceed the tool’s maximum

air pressure rating. If tool still does

not have sufficient force at maximum

pressure and sufficient airflow, then a

larger tool may be required.

10. Once nut is tightened, release

Trigger. Turn off the air supply and

disconnect the hose.

11. If available, check the recommended

torque specification for the nut. Use

a torque wrench to tighten the nut

to the proper setting after using the

Impact Wrench.

12. To set Impact Wrench in Reverse,

slide Reverse Valve to the

right for

counterclockwise (reverse) rotation.

Then adjust air flow by turning Air

Regulator Knob from positions 1

through 5. Position 1 allows the

lowest amount of air flow, and

Position 5 the highest.

13.

WARNING! Before changing the

rotational direction of the tool, release

the Trigger and allow the tool to come

to a complete stop.

14. When the nut is loosened, release

Trigger. Turn off air supply and

disconnect the hose. If needed,

remove the nut from the socket.

15. To prevent accidents, turn off the

tool, detach the air supply, safely

discharge any residual air pressure in

the tool, and release the throttle and/

or turn the switch to its off position

after use. Clean external surfaces of

the tool with clean, dry cloth. Then

store the tool indoors out of children’s

reach.