beautypg.com

Check or replace your filters, Replace the uvc bulb, Figure 10. replace the uvc bulb – Hunter Fan 44030-01 User Manual

Page 8: Figure 11, Figure 9

background image

8

©2010 Hunter Fan Co.

44030-01 20100119

figure 10.

replace The uVC bulb

The UVC light should be replaced once yearly. Follow

these instructions to remove and replace the UVC bulb.

1. Unplug the unit from the wall outlet and remove the

back grill by pressing down on the top tab.

2. Remove the 2 screws holding the Photcatalytic Screen

in place and remove the screen. Figure 9.

3. Remove the 3 screws holding the UVC Guard in place

and remove it from the unit. Figure 10. & 11.

4. Grasp the bulb with your thumbs and forefingers at

the plastic top and bottom and gently roll the bulb to

the left. Figure 12.

5. When the bulb releases, slide the top of the bulb out

of the bracket and remove.

6. Partially remove the new UVC Bulb from it’s packaging

being careful not to let the bulb come in contact with

your skin.

figure 11.

5. If the Pre-Filter needs to be cleaned, It may be

submerged in warm soapy water to clean. Gently lift

and submerge the filter several times to clean.

6. When complete, rinse the filter with warm water and

allow to dry completely.

Note: Wet parts placed into the unit can cause damage

to the filters and or the motor of the Air Purifier.

Check or replace your filters

1. Turn the Air Purifier off and disconnect from the wall.

2. Remove the rear grill on the back of the unit by

pressing the tab at the top of the unit, under the

handle and pull the rear grill outward. Figure 7.

3. Remove the HEPA Filters from the unit.

4. Check the Filters for particle build-up.

5. The HEPA filter should be removed every 12 months

of use and matched to the color indicator on the inside

of the filter compartment. When the filter matches the

dark, charcoal gray indicator, it should be replaced.