beautypg.com

He.l p–0 he.l p–1 he.l p–2, He.l p–3, He.l p–4 – Hobart Welding Products STELLAR AT OM-180 670Q User Manual

Page 28: He.l p–5 he.l p–6 he.l p–7, He.l p–8, He.l p–9

background image

OM-180 670 Page 24

5-3.

Voltmeter/Ammeter Help Displays

.

All directions are in reference to the front
of the unit. All circuitry referred to is lo-
cated inside the unit.

1

Help 0 Display

Indicates a shorted thermistor RT2 on the left
side of the unit. If this display is shown, con-
tact a Factory Authorized Service Agent.

2

Help 1 Display

Indicates a malfunction in the primary power
circuit. If this display is shown, contact a Fac-
tory Authorized Service Agent.

3

Help 2 Display

Indicates a malfunction in the thermal
protection circuitry located on the left side of
the unit. If this display is shown, contact a
Factory Authorized Service Agent.

4

Help 3 Display

Indicates the left side of the unit has over-
heated. The unit has shut down to allow the

fan to cool it (see Section 3-2). Operation will
continue when the unit has cooled.

5

Help 4 Display

Indicates a malfunction in the thermal
protection circuitry located on the right side
of the unit. If this display is shown, contact a
Factory Authorized Service Agent.

6

Help 5 Display

Indicates the right side of the unit has over-
heated. The unit has shut down to allow the
fan to cool it (see Section 3-2). Operation will
continue when the unit has cooled.

7

Help 6 Display

Indicates that the input voltage is too low and
the unit has automatically shut down. Opera-
tion will continue when the voltage is within
the acceptable lower range limit (15% below
the applicable input voltage). If this display is

shown, have an electrician check the input
voltage.

8

Help 7 Display

Indicates that the input voltage is too high
and the unit has automatically shut down.
Operation will continue when the voltage is
within the acceptable upper range limit (15%
above the applicable input voltage). If this
display is shown, have an electrician check
the input voltage. Help 7 can also indicate a
bus voltage imbalance.

9

Help 8 Display

Indicates a malfunction in the secondary
power circuit of the unit. If this display is
shown, contact a Factory Authorized Ser-
vice Agent.

10 Help 9 Display

Indicates a shorted thermistor RT1 on the
right side of the unit. If this display is shown,
contact a Factory Authorized Service Agent.

1

A

V

2

A

V

3

A

V

HE.L

P–0

HE.L

P–1

HE.L

P–2

4

A

V

HE.L

P–3

5

A

V

HE.L

P–4

6

A

V

7

A

V

8

A

V

HE.L

P–5

HE.L

P–6

HE.L

P–7

9

A

V

HE.L

P–8

10

A

V

HE.L

P–9